B-054 Development of a novel SCCA2 assay based on latex agglutination turbidimetric immunoassay

Toshitaro Takata, Wataru Takashima, Yoshinori Azuma

Key points

From the paper's conclusion
  • To address this limitation, we have developed a new SCCA2 measurement kit utilizing a latex agglutination turbidimetric immunoassay, compatible with standard automated biochemical analyzers.

Abstract

Background In recent years, the emergence of molecular targeted therapies for atopic dermatitis (AD) has significantly enhanced treatment efficacy. Consequently, the relevance of biomarkers in guiding treatment decisions and evaluating therapeutic outcomes has escalated. The measurement of squamous cell carcinoma antigen 2 (SCCA2) serves as a valuable tool for assessing the severity of pediatric atopic dermatitis. Serum SCCA2 levels have been shown to correlate strongly with the Severity Scoring of Atopic Dermatitis, an objective measure of disease activity in AD, and to effectively reflect treatment responsiveness. Similarly, the serum levels of thymus and activation-regulated chemokine (TARC) are also utilized for this purpose; however, unlike TARC, whose reference values vary with age, the reference values for SCCA2 remain consistent across all age groups. Since 2019, we have marketed an SCCA2 measurement kit (product name: IMMQUA SCCA2), which employs the enzyme-linked immunosorbent assay (ELISA) method. However, this method is time-consuming. To address this limitation, we have developed a new SCCA2 measurement kit utilizing a latex agglutination turbidimetric immunoassay, compatible with standard automated biochemical analyzers. Methods Two types of anti-SCCA2 antibodies were conjugated to latex particles to formulate the reagents. The fundamental performance of this assay was evaluated based on within-run reproducibility, linearity, limit of detection (LOD), potential interference from coexisting substances, and correlation. Within-run reproducibility was assessed by measuring three levels of control samples, each tested 20 times. Linearity was determined by diluting a high-concentration sample in ten incremental steps. The detection limit was established by analyzing blank samples alongside ten samples with concentrations near the LOD over a five-day period. For interference testing, bilirubin F, bilirubin C, hemoglobin, and chyle were added to pooled serum samples and measured. Correlation was evaluated by analyzing 100 serum samples from pediatric patients with AD using both the latex-based assay and the IMMQUA SCCA2, calculating the correlation coefficient and regression equation. All measurements were conducted using a Hitachi 7180 automatic analyzer, with calibration performed using a dedicated five-point standard solution. Results The performance parameters yielded the following results: Within-run reproducibility exhibited coefficients of variation ranging from 1.43% to 7.77%. Linearity was confirmed up to 31.83 ng/mL. The LOD was 0.30 ng/mL. In terms of interference, no significant effects were observed at levels up to 20 mg/dL for bilirubin F and bilirubin C, 500 mg/dL for hemoglobin, and 3000 FTU for chyle. Correlation analysis of the 100 serum samples measured using both methods revealed a correlation coefficient of r = 0.9989, with the regression equation expressed as y = 1.04 + 0.10. Conclusion The latex-based assay demonstrated robust performance, including a strong correlation with the existing kit, and is deemed effective for SCCA2 testing. Given that this assay can be conducted using an automated biochemical analyzer, it enables simpler and faster measurements compared to traditional ELISA kits. Therefore, it is anticipated to enhance the diagnostic process for AD.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers