B-049 qPCR Master Mixes with Probe and Primer Stabilization Using Capillary-Assisted Vitrification
Sankar Renu, Yolanda Peris-Taverner, Jenny Sharpe, Matthew Carroll, Mary Shank-Retzlaff, Laura Bronsart, Pravansu Mohanty
Key points
From the paper's conclusion- We report a Capillary-Assisted Vitrification (CAV) method that stabilizes biomolecules within one hour without freezing and/or boiling, yielding products with improved thermal stability suitable for ambient storage.
Abstract
Background Advancements in PCR reagent formulations have significantly improved the speed and sensitivity of PCR-based diagnostics. Ready-to-use master mixes incorporating all reaction components enhance efficiency, support high-throughput testing, and avoid separate primer and probe storage. We report a Capillary-Assisted Vitrification (CAV) method that stabilizes biomolecules within one hour without freezing and/or boiling, yielding products with improved thermal stability suitable for ambient storage. In this study, the CAV process was used to stabilize TaqMan qPCR master mixes containing FAM-labeled probes and primers targeting E. coli, and long-term stability was assessed at room temperature and 37°C. Methods CAV samples were prepared by combining 5× PrimePath Probe qPCR master mix, primers, and probe with Ambient BioFix+ buffer. The mixture was applied onto the Ambient BioFix scaffold (TAB-PU-01-7.5) and desiccated for 30 minutes using the Ambient Stabilizer. The stabilized samples were stored at room temperature and 37 °C for up to one year and evaluated at 1, 3, 6, and 12 months. On each testing date, the samples were rehydrated, mixed with E. coli genomic DNA template, and amplified alongside frozen PCR reagent controls using the QuantStudio™ 5 Real-Time PCR System. Results The CAV-stabilized samples produced cycle threshold (Ct) values comparable to the frozen liquid control, with Ct values of 8.7 and 7.9, respectively. As anticipated, both the control and CAV-stabilized reagents showed no/non-specific amplification in the no-template control (NTC), yielding Ct values = 30. CAV samples stored at room temperature and 37 °C for 1, and 12 months maintained amplification efficiency and Ct values similar to the frozen control. In contrast, liquid reagents stored at room temperature and 37 °C failed to detect the DNA template after 6 months of storage. Conclusion The CAV process rapidly stabilizes TaqMan qPCR master mixes with FAM-labeled probes and primers without freezing and/or boiling. The resulting ready-to-use reagents perform similarly to frozen controls and remain stable at both room temperature and 37 °C.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development of shelf-stable reagents and assay kits for bioluminescence applications using the capillary-assisted vitrification platform stabilization technology.PloS one · 2026
- Vacuum Drying Maintains the Integrity of DNA and Protects the Stability of PCR Amplification under Accelerated Aging.ACS omega · 2026
- Development and validation of the 6-dye lyophilized fluorescent multiplex PCR system.PloS one · 2026
- A-104 Compatibility of Copan UBM Transport Medium with Molecular Detection of STI Targets across Different qPCR AssaysClinical Chemistry · 2026
- Investigation on a Freeze-Drying Process for Long-Term Stability of mRNA-LNPsVaccines · 2026
- Simple ion-pairing reversed phase LC-UV method for the relative quantification of capping species in mRNA-based modalitiesJournal of Chromatography B · 2026