Clinical Chemistry

B-049 qPCR Master Mixes with Probe and Primer Stabilization Using Capillary-Assisted Vitrification

Sankar Renu, Yolanda Peris-Taverner, Jenny Sharpe, Matthew Carroll, Mary Shank-Retzlaff, Laura Bronsart, Pravansu Mohanty

Key points

From the paper's conclusion
  • We report a Capillary-Assisted Vitrification (CAV) method that stabilizes biomolecules within one hour without freezing and/or boiling, yielding products with improved thermal stability suitable for ambient storage.

Abstract

Background Advancements in PCR reagent formulations have significantly improved the speed and sensitivity of PCR-based diagnostics. Ready-to-use master mixes incorporating all reaction components enhance efficiency, support high-throughput testing, and avoid separate primer and probe storage. We report a Capillary-Assisted Vitrification (CAV) method that stabilizes biomolecules within one hour without freezing and/or boiling, yielding products with improved thermal stability suitable for ambient storage. In this study, the CAV process was used to stabilize TaqMan qPCR master mixes containing FAM-labeled probes and primers targeting E. coli, and long-term stability was assessed at room temperature and 37°C. Methods CAV samples were prepared by combining 5× PrimePath Probe qPCR master mix, primers, and probe with Ambient BioFix+ buffer. The mixture was applied onto the Ambient BioFix scaffold (TAB-PU-01-7.5) and desiccated for 30 minutes using the Ambient Stabilizer. The stabilized samples were stored at room temperature and 37 °C for up to one year and evaluated at 1, 3, 6, and 12 months. On each testing date, the samples were rehydrated, mixed with E. coli genomic DNA template, and amplified alongside frozen PCR reagent controls using the QuantStudio™ 5 Real-Time PCR System. Results The CAV-stabilized samples produced cycle threshold (Ct) values comparable to the frozen liquid control, with Ct values of 8.7 and 7.9, respectively. As anticipated, both the control and CAV-stabilized reagents showed no/non-specific amplification in the no-template control (NTC), yielding Ct values = 30. CAV samples stored at room temperature and 37 °C for 1, and 12 months maintained amplification efficiency and Ct values similar to the frozen control. In contrast, liquid reagents stored at room temperature and 37 °C failed to detect the DNA template after 6 months of storage. Conclusion The CAV process rapidly stabilizes TaqMan qPCR master mixes with FAM-labeled probes and primers without freezing and/or boiling. The resulting ready-to-use reagents perform similarly to frozen controls and remain stable at both room temperature and 37 °C.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers