A-405 Evaluating Saliva as a Potential Sample Matrix for Point-of-Care Screening of Biotin-Mediated Immunoassay Interference
Preejith Vachali, Gordon Schroeder, Matthew Dee, Edmunds Reineks
Key points
From the paper's conclusion- Initial lateral flow results support the feasibility of a saliva-based point-of-care screen to reduce biotin-mediated immunoassay interference prior to venipuncture.
Abstract
Background Biotin interference remains a well-recognized source of error in biotin/streptavidin-based immunoassays and can result in falsely increased or decreased results across many clinically important assays. Although several newer assay formulations incorporate biotin-tolerance and other mitigation strategies, older legacy platforms and patients taking mega-dose biotin supplementation remain susceptible to interference. Proactive screening for elevated biotin prior to venipuncture could mitigate avoidable repeat testing, reporting delays, and downstream clinical risk. Because saliva is a noninvasive and operationally compatible matrix for point-of-care (POC) workflows, our initial objective was to determine whether biotin could be detected in saliva using a commercially available ELISA kit. Following confirmation of biotin detectability, we evaluated a lateral-flow dipstick (LFD) to assess saliva matrix compatibility and feasibility for POC screening. Methods We evaluated eight saliva specimens purchased from a clinical laboratory using commercially available biotin ELISA and LFD kits (Attogene, USA). The ELISA kit employs a competitive design, in which sample biotin competes with biotin–BSA for binding to plate-bound anti-biotin antibodies. Bound antibody was detected using HRP/TMB, resulting in an absorbance (450 nm) inversely proportional to biotin concentration. Each specimen was measured in triplicate, following the manufacturer’s instructions. For LFD testing, the kit utilizes a competitive test-line format, where higher biotin concentrations reduce test-line intensity. Saliva or controls were mixed with the kit running buffer in a microplate well, the dipstick was incubated for 10–15 minutes, and results were visually interpreted according to the manufacturer’s protocol. Results All eight saliva specimens yielded measurable biotin concentrations, ranging approximately from 3 to 8 ng/mL (Figure 1A). Triplicate measurements demonstrated acceptable within-run precision for all samples (CV less than 15%), with most specimens exhibiting CVs between 2% and 6 %, indicating stable performance across this range. Consistent with these low concentrations, the corresponding LFD results showed strong test lines across all unspiked samples. To confirm that LFD signals decrease with increasing biotin levels, one specimen was spiked to approximately 8 ng/mL when accounting for the running buffer, and the spiked sample’s test-line suppression closely matched the corresponding standard (8.33 ng/mL) (Figure 1B). These observations demonstrate that both ELISA and LFD provide consistent qualitative and quantitative assessments of biotin in saliva across the tested range. Conclusion Our initial evaluation demonstrated that saliva is a viable, noninvasive matrix for quantitative biotin measurement by ELISA. Initial lateral flow results support the feasibility of a saliva-based point-of-care screen to reduce biotin-mediated immunoassay interference prior to venipuncture. Planned studies will analyze matched saliva and serum samples (pending IRB approval) to define saliva–serum biotin correlations and establish threshold concentrations necessary for guiding the development of a point-of-care lateral-flow device.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Mitigating the deleterious impact of saliva on cell-free expression sensors for point-of-use diagnostics.Synthetic biology (Oxford, England) · 2026
- Saliva as an Alternative Matrix for Antibiotic Pharmacokinetics and Therapeutic Drug Monitoring: Current Evidence and Future Directions: A Narrative Review.Infectious diseases and therapy · 2026
- From urine to serum: blood-based matrices reshape the future of anti-doping testing.Bioanalysis · 2026
- Methodological Considerations in Saliva‐Based Biomarker Research: Addressing Patient‐Specific Variability in Translational Research ProtocolsCurrent Protocols · 2025
- Biotin-specific molecularly imprinted polymers as a biomimetic test line in lateral flow assaysBiosensors and Bioelectronics · 2026
- Observed Clinical and Operational Factors Are Associated with Biomarker Test Utilization in Respiratory Virus RT-PCR Testing: A Real-World Analysis of Inflammatory, Cardiac, and Thrombotic Biomarkers.Diagnostics (Basel, Switzerland) · 2026