Clinical Chemistry

A-394 Development and evaluation of field-deployable method for flash-freezing sensitive specimens within low-cost vacuum insulated canisters

Ulrich Schaff, Gabriella Iacovetti, Nicolas Tokunaga, Mitchell Peevler, Greg Sommer

Key points

From the paper's conclusion
  • Here we introduce a technique to produce temperatures <-20°C on site using conventional water ice combined with prepacked non-hazardous solutes with ultra-low eutectic temperatures.

Abstract

Background Numerous clinical analytes are sensitive to thermal degradation and require specimens to be transported in a frozen state to maintain stability. Highly unstable analytes such as amyloid peptides, incretins, and catecholamines require rapid freezing rates for optimal preservation. The majority of collection sites do not have ready access to hazardous flash freezing solutions such as liquid nitrogen or dry-ice solvent baths. Furthermore, for field collections even access to consumer-grade ∼-18°C freezers may be constrained. Here we introduce a technique to produce temperatures <-20°C on site using conventional water ice combined with prepacked non-hazardous solutes with ultra-low eutectic temperatures. Methods A series of water ice-solute mixtures, including Ethanol, Methanol, and MgCl2 brine were tested when preconditioned at -18°C (comparable to a consumer-grade freezer) or at 0°C (comparable to commonly available bulk bag ice). The ice was combined with solute in a 50:50 ratio within a consumer-grade screwtop 18oz vacuum insulated flask. A specimen tube was immersed in the flask, which was then sealed and manually shaken end-over-end for 2 minutes (“Boston shaker” technique). Temperature within the specimen tube was monitored over the course of 12 hours with fine resolution over the first 10 minutes. Freezing rate for specimen tubes were compared between the solute-ice mixtures and a -80°C freezer. Results The internal temperature of all vacuum flasks reached below -20°C almost immediately upon agitation and maintained sub-zero temperatures for more than 12 hours. For all tested solutes, specimen tubes were frozen within 1 minute compared to 12 minutes for a -80C freezer. Minimum temperature was -29.6C for Ethanol, -29.7C for MgCl2, and -37.8C for Methanol. Conclusion Specimen freezing rates achieved with manual ice-solute agitation were ∼10x faster than a -80°C freezer. The technique can be executed with low-cost and commonly available materials and enables sustained short-term temperatures colder than a consumer grade freezer in a hand-portable format. The flash freezing solutions were safely contained in an inexpensive leak-proof, and highly insulated vessel. This may be useful a useful technique for preserving highly unstable sample types in home-like environments or field conditions such as employee health screenings until the specimen can be transferred to the cold chain.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

A-394 Development and evaluation of field-deployable method for flash-freezing sensitive specimens within low-cost vacuum insulated canisters — Science Skim