Clinical Chemistry

A-349 A Dual-Marker Panel Predicts the Likelihood of Biliary Atresia in Infants with Superior Specificity than Current Practice

Wen Gu, Kevin Cui, Qiong Wu, Jing Cao

Key points

From the paper's conclusion
  • This study evaluated the diagnostic performance of MMP-7 in combination with age, gender, and hepatic panel markers to develop a non-invasive predictive model that improves specificity without compromising sensitivity.

Abstract

Background Timely diagnosis of biliary atresia (BA) is a critical challenge in pediatric hepatology, as the efficacy of the Kasai portoenterostomy significantly decreases with age. Consequently, rapid differentiation of BA from other causes of neonatal cholestasis is essential. Current diagnostic algorithms relying on hepatic panel blood tests (total bilirubin [TBil], direct bilirubin [DBil], gamma-glutamyl transferase [GGT]), abdominal ultrasound, hepatobiliary scintigraphy, and liver biopsy are often limited by lack of sensitivity and specificity, operator dependence, or invasiveness. While matrix metalloproteinase-7 (MMP-7) has been identified as a highly sensitive biomarker for BA (Yang et al. Hepatology 2018), the proposed cutoff of >18.2 ng/mL was derived from a cohort where BA was over-represented (>50%) (Pandurangi et al. Hepatology 2024). Thus, this single-marker threshold may lack sufficient specificity in real-world screening populations, potentially leading to unnecessary surgical exploration in infants with non-BA cholestasis. This study evaluated the diagnostic performance of MMP-7 in combination with age, gender, and hepatic panel markers to develop a non-invasive predictive model that improves specificity without compromising sensitivity. Methods We prospectively followed infants undergoing workup for cholestasis at a pediatric tertiary care center between July 2023 and June 2025 with paired serum MMP-7 and hepatic panel results collected within a 7-day window. MMP-7 was quantified using the same time-resolved fluorescence energy transfer immunoassay (Revvity, San Mateo, California, USA) as in Pandurangi et al. A Random Forest machine learning model with Repeated Stratified K-Fold Cross-Validation was utilized to test multivariate algorithms and assess feature importance against the gold standard of intraoperative diagnosis. Results The cohort included 155 patient encounters (median age 41.2 days, 65% male) with 14 confirmed BA cases. We analyzed the contribution of age, MMP-7, bilirubin (TBil, DBil, ratio), and GGT levels relative to assay- and age-specific reference intervals to the prediction of BA. MMP-7 was the dominant predictive feature (importance: ∼43%), followed by GGT (∼17%), DBil (∼11%), TBil, DBil/TBil ratio, age and gender. Applying the threshold of >18.2 ng/mL in current practice as suggested by Pandurangi et al to this cohort yielded 100% sensitivity but a poor specificity of 56.7%. In contrast, an MMP-7/GGT dual-marker panel maximizes sensitivity at 100% and specificity at 97.2%. MMP-7 over 82 ng/mL provides high confidence for BA diagnosis while MMP-7 less than 33.7 ng/mL rules out BA. Between MMP-7 of 33.7 and 82 ng/mL, GGT greater than 1.5 times the upper reference limit (URL) confirms BA in 12 out of 15 cases (Figure). The false-positive results (n=3) occurred in complex patients with comorbidities such as liver fibrosis. Conclusion A dual-marker panel of MMP-7 and GGT significantly outperforms the current single-marker MMP-7 testing strategy. By raising the threshold for MMP-7 and incorporating GGT, this panel effectively excludes most non-BA cholestasis cases that would otherwise screen positive. This approach offers a superior, non-invasive tool to guide surgical decision-making and reduce unnecessary procedures in diagnosing BA.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers