A-343 A plasma amino acid LC-MS/MS method for the diagnosis and monitoring of inborn errors of metabolism patients

Adam Ptolemy, Young Kim, Chris MacDonald, Alexander Kolb, Mark Kellogg, Roy Peake

Key points

From the paper's conclusion
  • Background Quantitative plasma amino acid analysis is essential for the diagnosis and monitoring of inborn errors of metabolism (IEM).

Abstract

Background Quantitative plasma amino acid analysis is essential for the diagnosis and monitoring of inborn errors of metabolism (IEM). Chromatographic amino acid methods utilizing optical detectors are prone to interferences and limited by long analytical run times. We describe the development and validation of a liquid chromatography–tandem mass spectrometry (LC MS/MS) assay designed to provide rapid, sensitive, and interference resistant plasma amino acid testing for pediatric IEM patients. Methods Method development and clinical validation studies were performed using an Acquity™ iClass UPLC coupled to Xevo TQ-S Micro tandem mass spectrometer (Waters Corporation) operated in positive electrospray ionization mode (ESI+). Sample pretreatment was performed using a Kairos™ Amino Acid Kit (Waters Corporation), which utilizes protein precipitation and AccQTag® chemical derivation prior to analysis. Optimization of the sample preparation protocol permitted the use of 20 µL of plasma for testing. All amino acids (N=45) and internal standards were detected as their derivatized products using their respective MS/MS transitions. Column chemistry, mobile phase composition, flow rate and gradient conditions were optimized to provide the greatest isobaric amino acid resolution and sensitivity, within the shortest analytical runtime. Performance of the LC-MS/MS assay was initially evaluated through assessments to precision and accuracy. Results An ACCQ-TAG™ Ultra C18 (2.1 x 150 mm, 1.7µm, Waters Corporation) column with mobile phase compositions of 0.1% (v/v) formic acid in water and acetonitrile provided the highest resolution of all isobaric amino acids, including isoleucine and alloisoleucine (Rs 0.85). Under the devised gradient conditions of this method, which utilized a flow rate of 0.5 mL/min and column temperature of 55°C, all amino acids were eluted within a 17 min runtime. The optimized sample preparation and chromatographic conditions yielded an LC-MS/MS assay that was linear over a wide amino acid concentration range (5 to 1000 or 4000 µM, R>0.99) for all analytes. Average intra-day precision (N=10) of the low and high Kairos kit QC was 2.8% and 2.0%. The average inter-day precision (N=30) of this QC was 9.7% and 5.9%. LC-MS/MS derived plasma amino acid results had an acceptable bias relative to our current LC-UV method, with an average recovery of 113%. A blinded split sample analysis with a national reference laboratory also demonstrated good agreement, with an average plasma amino acid recovery of 102% relative to the reference laboratory mean. The accuracy of this protocol was further challenged by testing archived amino acid EQA material (N=7 samples) from ERNDiM. Good agreement relative to the ERDiM all method laboratory means were achieved, with amino acid (N=28) recoveries ranging from 93% (sulfocysteine) to 121% (glutamine) and a median recovery of 104%. Conclusion We have developed an accurate, precise and efficient LC-MS/MS method for plasma amino acids using the Kairos™ Amino Acid kit. The method requires minimal sample volume (20 µL), achieves full amino acid profiling within a short 17 min analytical runtime, and demonstrates strong agreement with reference standards. These features make the assay well suited for clinical testing in pediatric IEM populations.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers