Clinical Chemistry

A-254 Biological Variation of Hematological Parameters in a Highland people

Billy Sanchez-Jacinto, Margot Faustino, Pierina Patricio - Alvino, Anabel Huaman - Cerva, Isabel Mendoza - Carbajal, Luisa Salcedo

Key points

From the paper's conclusion
  • The data analysis was performed for estimation of biological variation and estimation of analytical performance specifications (APS) using the statistical software Analyse-it for Microsoft Excel version 5.80.2, and graphs were created using GraphPad Prism software version 10.2.3.

Abstract

Background Biological variation comprises a within-subject biological variation intraindividual (CVi) and the between-subject biological variation interindividual (CVg) component. Its usefulness lies in obtaining analytical quality specifications and reference values for change (RVCs) according to population. Differences between hematological parameters can be influenced by various factors such as genetics, nutrition, and geographic altitude, among others. In Peru, there is limited scientific literature on biological variation in high-altitude Andean populations. The aim was to determine the biological variation of hematological parameters in people living at high altitude. Methods It´s was a descriptive, prospective, and longitudinal study. Fourteen healthy volunteers (6 women and 8 men, 4 weeks) aged 20 to 45 years were evaluated from Peru after inclusion and exclusion criteria. A total of 56 blood samples were collected during the study period in the city of Huaraz (3,000 m.a.s.l.). Measurements were performed using the Abbott CELL-DYN Emerald 22 analyzer. The data analysis was performed for estimation of biological variation and estimation of analytical performance specifications (APS) using the statistical software Analyse-it for Microsoft Excel version 5.80.2, and graphs were created using GraphPad Prism software version 10.2.3. Results The hematological parameters, CVi and CVg were found in erythrocytes (6.7% and 16.22%), hemoglobin (3.5% and 17.5%), leukocytes (9.6% and 7.81%), and platelets (12.3% and 13.15%). The CVR of neutrophils, lymphocyte and platelets was greater than 35%. On the other hand, the individuality index (II) showed high individuality (II>0.6) values for MCH, leukocytes, lymphocytes, neutrophils and platelets. The desirable APS for erythrocyte and hemoglobin were 3.35 and 1.75 for precision, 4.39% and 4.46%for bias, respectively. Conclusion The study demonstrated significant variability in the CVg of hematological parameters. Furthermore, leukocytes and series exhibited high individuality; therefore, reference intervals may not be suitable for high-altitude populations, and further research is needed to establish specific reference ranges.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers