Clinical Chemistry

A-235 Optimizing Blood Utilization in Cardiovascular Operating Rooms: A Quality Improvement Initiative

Angela Lauster, Mason Pearce, Nichole Synn, Karley Wright

Key points

From the paper's conclusion
  • Background Operating rooms are responsible for 30–70% of hospital red blood cell (RBC) waste despite accounting for only a small proportion of transfusions.

Abstract

Background Operating rooms are responsible for 30–70% of hospital red blood cell (RBC) waste despite accounting for only a small proportion of transfusions. Persistent blind spots in reporting and traceability within our Cardiovascular Operating Rooms (CVTOR) impaired the ability to accurately measure and reduce waste. This initiative aimed to decrease RBC waste by addressing data gaps, variability in provider practice, and workflow limitations through a phased set of interventions integrating standardized reporting, behavior based education, and multimodal tracking technologies. Methods A retrospective review of CVTOR RBC waste from January 2023 to December 2025 was conducted. Baseline performance was defined as the pre intervention phase prior to implementation of standardized waste reporting in RL6 (January–November 2023). Sequential PDSA cycles included: (1) adoption of structured RL6 waste categories; (2) targeted provider education aligned with Choosing Wisely principles; (3) room level visual management using magnet based tracking; and (4) deployment of Bluetooth enabled asset tracking through Intelligent Locations. The primary measure was waste per 100 cases. Root cause review distinguished process/system failures from manual non compliance such as out of temperature exposures and improper transport practices. Results Surgical volume increased 12.3% from 2023 (5,040 cases) to 2025 (5,660 cases). Baseline waste averaged 9.81 units/100 cases. Following implementation of standardized reporting and subsequent interventions (December 2023–November 2025), waste declined to 6.74 units/100 cases, representing a sustained 31% reduction relative to baseline. Annual waste rates fell by 42%, from 9.66 units/100 cases in 2023 to 5.58 in 2025. Monthly variability improved markedly (SD 3.20?1.84). Manual compliance lapses—including out of temperature incidents—accounted for the majority of remaining outlier months. Using a conservative loaded unit cost of $250, avoided waste in 2025 totaled 231 units, yielding approximately $57,750 in savings. Conclusion Standardized reporting paired with workflow embedded visual cues and multidisciplinary accountability produced a durable reduction in CVTOR RBC waste despite increasing surgical volume. While advanced tracking technologies enhanced traceability, the greatest improvements stemmed from human centered, operational interventions. This framework provides a scalable model for perioperative blood stewardship and demonstrates the impact of aligned clinical, informatics, and operational practices on waste reduction.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

A-235 Optimizing Blood Utilization in Cardiovascular Operating Rooms: A Quality Improvement Initiative — Science Skim