A-233 Clinical Validity of the AI-Based UIMD PBIA(Peripheral Blood Image Analyzer) in Leukopenic Samples (WBC <1.0×10^9/L)
Y U JONGHOON, Bowon Jung, Kwang Young Lee
Key points
From the paper's conclusion- These results show that the PBIA may provide valuable support for clinical interpretation and practical utility in peripheral blood smear analysis for leukopenic patients.
Abstract
Background Peripheral blood smear examination in samples with markedly decreased white blood cell (WBC) counts is inherently challenging due to limited observable cells, which may reduce the accuracy and reproducibility of manual microscopic differential counts. This study evaluates the analytical performance and reliability of UIMD’s PBIA, the AI-based automated blood cell classification system, and to assess the clinical validity of the PBIA in leukopenic samples under low cellularity conditions. Methods A total of 62 peripheral blood smear samples with leukopenia (WBC <1.0×10^9/L) were analyzed. The PBIA pre-classification results were compared with expert re-classification results using a confusion matrix to assess classification accuracy. Correlation analysis was additionally performed between the PBIA results and reference manual microscopic differential counts. A particular emphasis was placed on evaluating the detection performance of blast cells, which are clinically critical in leukopenic patients. Results The classification accuracy of the PBIA pre-classification was 95.3% compared to expert re-classification results. Correlation analysis between the PBIA and manual microscopic differential counts demonstrated high overall agreement across major leukocyte categories (r = 0.88). Notably, blast cell detection showed a strong correlation with manual results (r = 0.87), indicating stable detection performance even in samples with markedly reduced WBC counts. These findings suggest that the PBIA maintains consistent classification performance for samples with low cellularity conditions. Conclusion The PBIA demonstrated high classification accuracy and meaningful correlation with manual microscopic examination in leukopenic samples. In particular, stable blast detection performance supports the clinical reliability of the PBIA in low cellularity conditions. These results show that the PBIA may provide valuable support for clinical interpretation and practical utility in peripheral blood smear analysis for leukopenic patients.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- AI-assisted digital peripheral blood morphology multicenter randomized paired method clinical validation study.NPJ digital medicine · 2026
- Comprehensive Multicenter Evaluation of an AI-Based Deep Learning System for Automated Blood Cell Classification and Morphologic Analysis.International journal of laboratory hematology · 2026
- A-251 Rapid AI-Based Detection of Acute Promyelocytic Leukemia from Digital Blood SmearsClinical Chemistry · 2026
- Classification of Benign Hematogones and B-cell Acute Lymphoblastic Leukemia in Peripheral Blood Smear Images Using Artificial Intelligence.Cureus · 2026
- PV-WTConv: a parallel network for abnormal white blood cell classification based on wavelet transform convolution.Frontiers in medicine · 2026
- Exhaustive white blood cell extraction and profiling across whole-slide images of blood and bone marrow smearsmedRxiv · 2026