Abstract

Background Peripheral blood smear examination in samples with markedly decreased white blood cell (WBC) counts is inherently challenging due to limited observable cells, which may reduce the accuracy and reproducibility of manual microscopic differential counts. This study evaluates the analytical performance and reliability of UIMD’s PBIA, the AI-based automated blood cell classification system, and to assess the clinical validity of the PBIA in leukopenic samples under low cellularity conditions. Methods A total of 62 peripheral blood smear samples with leukopenia (WBC <1.0×10^9/L) were analyzed. The PBIA pre-classification results were compared with expert re-classification results using a confusion matrix to assess classification accuracy. Correlation analysis was additionally performed between the PBIA results and reference manual microscopic differential counts. A particular emphasis was placed on evaluating the detection performance of blast cells, which are clinically critical in leukopenic patients. Results The classification accuracy of the PBIA pre-classification was 95.3% compared to expert re-classification results. Correlation analysis between the PBIA and manual microscopic differential counts demonstrated high overall agreement across major leukocyte categories (r = 0.88). Notably, blast cell detection showed a strong correlation with manual results (r = 0.87), indicating stable detection performance even in samples with markedly reduced WBC counts. These findings suggest that the PBIA maintains consistent classification performance for samples with low cellularity conditions. Conclusion The PBIA demonstrated high classification accuracy and meaningful correlation with manual microscopic examination in leukopenic samples. In particular, stable blast detection performance supports the clinical reliability of the PBIA in low cellularity conditions. These results show that the PBIA may provide valuable support for clinical interpretation and practical utility in peripheral blood smear analysis for leukopenic patients.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

A-233 Clinical Validity of the AI-Based UIMD PBIA(Peripheral Blood Image Analyzer) in Leukopenic Samples (WBC <1.0×10^9/L) — Science Skim