A-168 Quantifying the Dawn Phenomenon Using a Probabilistic CGM Framework Identifies gamma--Glutamyl Transferase as a Novel Biomarker in Type 1 Diabetes
Naoki Sakane, Seiko Sakane
Key points
From the paper's conclusion- Conclusion Using a probabilistic CGM-based framework that accounts for sensor error, we identified gamma--glutamyl transferase as a robust and consistent biomarker associated with the magnitude of the dawn phenomenon in individuals with type 1 diabetes.
Abstract
Background The dawn phenomenon (DP) is defined as early-morning hyperglycemia or an increased insulin requirement to maintain normoglycemia in the absence of antecedent nocturnal hypoglycemia. It is commonly observed in individuals with diabetes and represents a clinically important disturbance of glucose regulation during the early morning hours. DP contributes to increased glycemic variability, complicates insulin titration, and may increase the risk of long-term diabetes-related complications. Although counterregulatory hormones such as growth hormone and cortisol, as well as increased hepatic glucose production, have been implicated in its pathophysiology, the mechanisms underlying interindividual variability in DP remain incompletely understood. In particular, objective and clinically accessible biomarkers for identifying and characterizing DP are limited. This study aimed to quantify DP using a probabilistic computation framework based on continuous glucose monitoring (CGM) data that explicitly accounts for sensor error, and to identify novel biomarkers associated with DP magnitude. Methods We analyzed data from 317 adults with diabetes enrolled in the FGM-Japan study. CGM data were obtained using the FreeStyle Libre system (Abbott Diabetes Care, Alameda, CA, USA) over the 90 days preceding enrollment. DP was defined as an early-morning glucose rise of =20 mg/dL in the absence of antecedent nocturnal hypoglycemia and was quantified using a probabilistic computation framework incorporating CGM sensor error to estimate the probability and magnitude of DP occurrence. Multivariable linear regression analyses were conducted to identify factors associated with DP magnitude, and k-means clustering was used to explore phenotypic patterns. Sensitivity analyses applied alternative DP thresholds of =10 mg/dL and =30 mg/dL. Lifestyle characteristics and laboratory variables, including liver enzymes, were extracted from medical records. Results Among individuals with type 1 diabetes, multivariable linear regression analysis showed that DP magnitude defined by a =20 mg/dL early-morning glucose rise was independently associated with male sex (ß = 4.3, 95% CI 0.6 to 8.0, P = 0.022), shorter diabetes duration (ß = -0.16 per year, 95% CI -0.32 to -0.01, P = 0.037), higher HbA1c (ß = 2.7, 95% CI 1.0 to 4.5, P = 0.002), and higher gamma--glutamyl transferase (GGT) levels (ß = 0.16, 95% CI 0.07 to 0.26, P = 0.001). The model was statistically significant (adjusted R² = 0.12, P < 0.001), with no evidence of multicollinearity. Sensitivity analyses yielded consistent results: using thresholds of =10 mg/dL and =30 mg/dL, GGT remained a significant predictor of DP magnitude, whereas the association with diabetes duration was attenuated at the highest threshold. Across all definitions, GGT showed a robust and independent association with DP magnitude. Conclusion Using a probabilistic CGM-based framework that accounts for sensor error, we identified gamma--glutamyl transferase as a robust and consistent biomarker associated with the magnitude of the dawn phenomenon in individuals with type 1 diabetes. Given its role in oxidative stress regulation, inflammatory processes, and intracellular redox homeostasis, GGT may reflect underlying metabolic and hepatic mechanisms contributing to early-morning dysglycemia beyond traditional hormonal explanations. These findings suggest that GGT may serve as a clinically accessible marker for risk stratification and personalized management of the dawn phenomenon.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Factors associated with the dawn phenomenon in adults with type 1 diabetes: a probabilistic continuous glucose monitoring analysis.Endocrine journal · 2026
- Association Between Short-Term Glycemic Variability Measured by Continuous Glucose Monitoring and Early Diabetic Kidney Disease in Type 2 Diabetes.Diabetes, metabolic syndrome and obesity : targets and therapy · 2026
- Hepatic steatosis is associated with postprandial dysglycemia in type 1 diabetes: insights from dual-modality liver assessment.Frontiers in medicine · 2026
- Lack of Association Between Hemoglobin A1c and Continuous Glucose Monitor Metrics Among Individuals with Prediabetes and NormoglycemiaDiabetes Technology & Therapeutics · 2025
- Association of Continuous Glucose Monitoring-Based Nocturnal Glucose Patterns With Microvascular Complications in Patients With Type 2 Diabetes.Diabetes, obesity & metabolism · 2026
- Glycated albumin: An old yet new biomarker in people with diabetes and the potential for novel applications.Journal of diabetes investigation · 2026