Clinical Chemistry

A-157 Clinical Performance of LC-MS/MS and Immunoassays for Serum Thyroglobulin in Assessing Structural Disease in Differentiated Thyroid Cancer

Yichen Ma, xinqi cheng, Ling Qiu

Key points

From the paper's conclusion
  • We compared the proportions of undetectable Tg results and evaluated diagnostic performance for structural persistence/recurrence using ROC curve analysis in TgAb-negative and TgAb-positive subgroups.

Abstract

Background Serum thyroglobulin (Tg) is central to postoperative surveillance in differentiated thyroid carcinoma (DTC), yet Tg immunoassays can be biased by thyroglobulin antibodies (TgAb). We evaluated the analytical agreement and clinical performance of four automated Tg immunoassays against a liquid chromatography-tandem mass spectrometry (LC-MS/MS) Tg method, with emphasis on TgAb-positive patients. Methods Tg was measured using four automated immunoassays (Siemens, Roche, Mindray, and Mindray 2.0) and an LC-MS/MS method. LC-MS/MS is considered resistant to TgAb interference; Mindray 2.0 is designed to mitigate TgAb interference. TgAb was measured using the corresponding immunoassay reagents for each platform. A total of 149 residual serum samples from routine Tg/TgAb testing at Peking Union Medical College Hospital were collected for method comparison (n=149). Method agreement with LC–MS/MS was evaluated using Passing-Bablok regression and Bland–Altman analysis. We included 256 patients with histologically confirmed DTC who had undergone total thyroidectomy at least 3 months previously and structural persistence/recurrence was identified in 109 patients. We compared the proportions of undetectable Tg results and evaluated diagnostic performance for structural persistence/recurrence using ROC curve analysis in TgAb-negative and TgAb-positive subgroups. Results In TgAb-negative samples, immunoassays showed consistently strong correlations with LC–MS/MS (Spearman r=0.934–0.963), with mean relative biases versus LC–MS/MS ranging from -15.1% to +10.7%. In TgAb-positive samples, correlations varied more (r=0.852–0.973) and bias patterns diverged: Mindray 2.0 showed a negative mean bias (-22.2%), whereas Siemens, and Mindray showed positive mean biases (+95.2%, +49.8%, and +50.2%, respectively). Among postoperative DTC patients with structural persistence/recurrence, detectability differed by TgAb status. In the TgAb-positive group (n=34), using the LOQ threshold, the detectable proportions were 38% (13/34) for Siemens, 38% (13/34) for Roche, 59% (20/34) for Mindray, 35% (12/34) for Mindray 2.0, and 21% (7/34) for LC–MS/MS; using the guideline-defined medical decision limits, detectability was 21% (7/34) for Siemens, 21% (7/34) for Roche, 21% (7/34) for Mindray, 24% (8/34) for Mindray 2.0, and 26% (9/34) for LC–MS/MS. In the TgAb-negative group (n=75), detectability was broadly comparable across all methods, with 96%–100% of results above LOQ and 96% above the guideline-defined medical decision limits. In the 256 post-thyroidectomy DTC cohort, the areas under the curve (AUCs) for discriminating structural persistence/recurrence in TgAb-negative patients were 0.999 for Siemens, 0.980 for Roche, 0.999 for Mindray, 0.999 for Mindray 2.0, and 0.992 for LC–MS/MS, whereas AUCs in TgAb-positive patients were 0.647, 0.677, 0.650, 0.754, and 0.725, respectively. Conclusion In TgAb-positive samples, the two TgAb-resistant methods (Mindray 2.0 and LC–MS/MS) showed good agreement. In TgAb-positive patients, TgAb-resistant methods improved detectability and achieved higher AUCs than conventional immunoassays. However, even TgAb-resistant methods detected only a subset of TgAb-positive structural cases, indicating a persistent surveillance blind spot in this population.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers