Clinical Chemistry

A-154 Comparison of Aldosterone: Renin Ratio by DiaSorin immunoassay vs LCMS for Primary Aldosteronism screening

Amas Lee, Bobby Li, Robert Hawkins

Key points

From the paper's conclusion
  • We aim to compare the clinical agreement of the ARR performed at a referral lab using a mass spectrometry method (ARR-MS) to an ARR performed on the DiaSorin immunoassay system (ARR-IA).

Abstract

Background The aldosterone renin ratio (ARR) is used as a screening test for primary aldosteronism (PA). We aim to compare the clinical agreement of the ARR performed at a referral lab using a mass spectrometry method (ARR-MS) to an ARR performed on the DiaSorin immunoassay system (ARR-IA). Methods Routine ARR requests are sent on dry ice to Mayo Clinic Laboratories for plasma renin activity (PRA) and aldosterone analysis by LCMS (Ald-LCMS). Samples collected between July-September 2025 with sufficient (>500 µL) excess EDTA plasma were frozen at -80°C. Prior to on-site analysis, aliquots were rapidly thawed at room-temperature on a roller-mixer, then direct renin concentration (DRC) and aldosterone (Ald-IA) were measured on a Diasorin Liaison XL. The ARR was calculated as follows: ARR-MS = Ald-LCMS (ng/dL) ÷ PRA (ng/mL/hr) ARR-IA = Ald-IA (pmol/L) ÷ DRC (mIU/L) A positive screening event was defined as >15 for ARR-MS and >70 for ARR-IA, using the Endocrine Society (ES) 2025 Primary Aldosteronism guideline. Cohen’s kappa coefficient was used to rate the agreement between the two ARRs. Results 159 pairs of ARRs were measured and 135 pairs could be assigned to either positive or negative screening status on both assays. The Cohen kappa coefficient was 0.87 (95% CI: 0.76 – 0.97), with 96% agreement. 23% (31/135) were positive screening test based on ARR-MS >15. 25 (81%) of these were also positive on ARR-IA. All 104 negative screening on the ARR-MS were also negative on the ARR-IA. 24/159 ARR-MS could not be assigned to a screening status due to renin or aldosterone being outside the clinical reporting range (CRR). 14 of these had both PRA and Ald-LCMS below the CRR, of these 11 had negative screening status by ARR-IA. The other 10 had PRA below the CRR and the Ald-LCMS was less than 9 ng/dL, resulting in equivocal screening status. Of these 10 patients, 4 had ARR-IA >70 (ie. positive screening status). Conclusion There was excellent agreement between the ARR-IA and ARR-MS when using the method-specific cut-off recommended by the 2025 ES Primary Aldosteronism Clinical Practice Guidelines. The ARR-IA is performed on an automated immunoassay platform and allows labs without technical expertise in LCMS to still provide a high-quality PA screening service.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

A-154 Comparison of Aldosterone: Renin Ratio by DiaSorin immunoassay vs LCMS for Primary Aldosteronism screening — Science Skim