A-145 Analytical Validation of the Ansh Labs Glucagon ELISA
Joshua Hunsaker, Sara Wyness, Sonia La’ulu, Fanjing Meng, Travis Moss, Jonathan Seiter, Joely Straseski
Key points
From the paper's conclusion- Conclusion The Ansh Labs Glucagon ELISA demonstrated strong analytical performance across all validation parameters.
Abstract
Background Glucagon is a peptide hormone secreted by pancreatic alpha-cells that maintains glucose homeostasis by stimulating hepatic glucose production. Measurement of circulating glucagon is performed to investigate inappropriate or excessive secretion, which may indicate glucagon-producing neuroendocrine tumors or contribute to metabolic disorders such as diabetes. The aim of this study was to validate the Ansh Labs glucagon enzyme-linked immunosorbent assay (ELISA) for clinical use as an alternative to a radioimmunoassay (RIA) method. Methods Accuracy, linearity, precision, analytical sensitivity, specificity, reference interval, analyte stability, dilution, and collection tube comparison studies were evaluated against predefined acceptance criteria and manufacturer specifications. Glucagon-spiked plasma was prepared for linearity, stability, and dilution studies. Accuracy was assessed using residual patient specimens tested by a validated RIA (ALPCO) that were collected in tubes containing protease inhibitor (Phe-Pro-Arg-chloromethylketone; PPACK; n=36). Linearity was evaluated using percent split dilutions (0, 25, 50, 75, 100%) and kit-provided calibrators. Precision was assessed using four replicates of each control across five runs. Analytical sensitivity was verified by running 10 replicates of calibrator A and 3 replicates of calibrator C and analyzing optical density (OD) values. Hemolytic interference was studied by spiking hemolysate into glucagon-spiked plasma across a range of hemoglobin concentrations (50–520 mg/dL), using a saline-spiked control for dilution correction. A reference interval was established using data from 120 fasting healthy individuals. Stability was assessed at ambient temperature (0–4 hours) and –20°C (1 month). Dilution performance was evaluated at 1:2, 1:4, and 1:8. Tube type effects were evaluated using paired PPACK and K2EDTA specimens (n=10) tested by ELISA and RIA. Results Accuracy studies showed acceptable qualitative agreement between ELISA and RIA (72.7% positive, 100% negative, 91.7% overall). Quantitative comparison showed a negative bias for ELISA relative to RIA (slope 0.920; bias –50.96%), consistent with manufacturer-supplied data. Linearity met acceptance criteria, with recoveries of 77.3–124.5% for split dilutions and 94.2–120.4% using calibrators. Within-run and total precision were <=7.8%CV. Analytical sensitivity met manufacturer claims (2.4 pg/mL). Hemolytic interference was observed across the tested range, resulting in –17.4% to –76.3% change from baseline and failing acceptance criteria, preventing extension beyond manufacturer limits (100 mg/dL). An upper reference limit of 150 pg/mL was established in fasting individuals. Stability was acceptable for up to 4 hours at ambient temperature and 1 month at –20°C (-9.48 to 5.97% change from baseline). Dilution studies supported 1:2 and 1:4 dilutions but not 1:8 dilutions (average recovery; 100.3%, 86.9%, 69.8% respectively). ELISA results were consistent between PPACK and K2EDTA tubes (bias –13.25%), indicating minimal tube-type impact. RIA values were consistently higher than ELISA across both specimen types (bias –34.29% to –43.00%), with greater divergence below the reference cutoff (<150 pg/mL; bias –57.98%). Conclusion The Ansh Labs Glucagon ELISA demonstrated strong analytical performance across all validation parameters. Comparable results from PPACK and K2EDTA specimens indicated that the tube types evaluated do not influence assay performance. The observed negative bias relative to RIA reflected method differences, highlighting the need for assay-specific interpretation and method-appropriate reference intervals when transitioning from RIA to ELISA.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluation of a new ELISA for fully automated detection of anti-GAD autoantibodies in type 1 diabetes and anti-GAD-associated neurological diseases.Clinica chimica acta; international journal of clinical chemistry · 2026
- GAD65 Antibody ELISA With Extended Reportable Range: Validation and Guidance for Neurological PracticeAnnals of Clinical and Translational Neurology · 2026
- Performance assessment of a novel fully automated ELISA for anti-IA2 autoantibody detection in type 1 diabetes.Clinica chimica acta; international journal of clinical chemistry · 2026
- Diagnostic Value of Serum Neutrophil Gelatinase-Associated Lipocalin for Adrenal Insufficiency.Chonnam medical journal · 2026
- 36 Free Glycerol Measurement Reveals Triglyceride Bias With Limited Categorical ImpactAmerican Journal of Clinical Pathology · 2026
- Impact of preanalytical sample handling on GLP-1 measurement in porcine plasma: A pilot ELISA-based study.Veterinarni medicina · 2026