A-110 The Jiddu Platform: Automated One-Hour Testing for Bacterial Detection and Antibiotic Sensitivity in Clinical Samples
Christopher Skipwith, Isabella Penafiel, Courtney Cavin, Mohan Tulapurkar, Michael Rouse
Key points
From the paper's conclusion- These results demonstrate technical feasibility for rapid bacterial detection in low-complexity specimens beyond urine.
Abstract
Background The need for new antibiotic susceptibility testing (AST) methods that deliver results in 1 hour or less for multiple specimen types is driven by the limitations of current culture-based methods, which are slow, often taking 48 hours to days. This delay in obtaining culture results forces clinicians to treat many infections empirically, which may not target the actual causative pathogen, particularly in the era of drug-resistant and multi-drug-resistant pathogens. Rapid AST using a variety of sample types from a single instrument—where urine, cerebrospinal fluid (CSF), and wound effluent are some of the most common clinically—could significantly improve clinical workflows. AST results from these specimen types could guide the treatment of infections such as complicated urinary tract infections (UTIs), urosepsis, meningitis, and wound infections, including those caused by MRSA, where timely treatment is essential for patient outcomes. Methods Our validated urine analysis cartridge was adapted for CSF and wound effluent by optimizing bacterial dilution factors to achieve detection thresholds of 10^5 CFU/mL (adult CSF and wound effluent) and 10^7 CFU/mL (pediatric CSF). Analytical performance was evaluated across two sensor units using sterile-filtered human urine and low-level bacterial samples. Limit of Blank (LOB) was determined from 10 replicates using non-parametric analysis (95th percentile of 40 ranked results). Limit of Detection (LOD) was estimated from 5 low-concentration samples using precision profile analysis with second-order polynomial fitting. Limit of Quantitation (LOQ) was established as the lowest concentration achieving <20% coefficient of variation (CV), determined from 16 replicates of 5 low-concentration samples using power function regression. Linearity was assessed by comparing mean replicate values against expected concentrations across a dilution series, and within-lab precision was evaluated across multiple days, operators, instruments, and cartridge lots. Results The system successfully detected bacteria in artificial CSF and culture-negative wound effluent, with buffer exchange recovering 84.79±7.67% (CSF) and 87.66±18.51% (effluent) of E. coli ATCC 25922 spiked at 10^5 CFU/mL (n=10 each; p=0.8934 between matrices). A minimum 2-mL CSF input volume yielded robust fluorescent signals above blank (n=20, p<0.0001). Fluorescence increased proportionally with bacterial concentration (10^1-10^5 CFU/mL), enabling infection/non-infection discrimination. Analytical performance varied by bacterial species and matrix. In urine, LOD/LOQ were 10^2/1.4×10^2 CFU/mL (E. coli) and 10^2/2.6×10^2 CFU/mL (K. pneumoniae). In artificial CSF, LOD/LOQ were 10^3/3.8×10^3 CFU/mL (S. pneumoniae) and 5×10^1/9.6×10^1 CFU/mL (H. influenzae). In wound effluent, LOD/LOQ were 5×10^2/7.1×10^2 CFU/mL (E. coli) and 10^2/1.2×10^2 CFU/mL (S. aureus). The assay demonstrated linearity from 1.5×10^4 to 7.5×10^4 CFU/mL across all matrices and organisms tested. Within-lab precision studies in all samples showed <15% coefficient of variation across different days, and cartridge lots. Conclusion The adapted cartridge successfully detected clinically relevant bacterial concentrations in CSF and wound effluent with high recovery rates (>84%), sensitive LODs (10^1-10^3 CFU/mL depending on organism), and robust analytical performance (<15% CV). The system effectively discriminated between contamination and infection at the diagnostic threshold of 10^5 CFU/mL across multiple pathogens and sample matrices. These results demonstrate technical feasibility for rapid bacterial detection in low-complexity specimens beyond urine. Future work will integrate AST capabilities into the platform and initiate preliminary clinical validation studies using patient samples to assess real-world performance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A rapid bacterial labeling method for phenotypic antimicrobial susceptibility testingDiagnostic Microbiology and Infectious Disease · 2025
- Next-generation point-of-care diagnostics for urinary tract infections: a systematic review of rapid pathogen detection methods.GMS infectious diseases · 2026
- Artificial Intelligence-Empowered Single-Cell Phenotyping for Rapid, Automated Pathogen Diagnostics.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
- Microfluidics for antimicrobial susceptibility testing: Current advances and future perspectivesBiomicrofluidics · 2026
- SERS-Based Universal AST: Rapid Treatment Guidance for Blood-Culture Bacteria before Species IdentificationAnalytical Chemistry · 2026
- Analytical performance and workflow impact of the FASTinov QUICKprep kit for direct bacterial identification and antimicrobial susceptibility testing from positive blood cultures.Journal of clinical microbiology · 2026