Clinical Chemistry

A-097 Quantitative assessment of circulating blood ESAT-6 for non-sputum identification of pulmonary tuberculosis

Sheng-Wei Pan, Mei-Lin Ho, Xiu-An Ye, Jia-Yih Feng

Key points

From the paper's conclusion
  • We evaluated whether circulating ESAT-6 levels can discriminate PTB and reflect the tuberculosis infection spectrum, with a focus on its potential use as a blood-based triage test in clinical settings where sputum-based diagnostics are limited or delayed.

Abstract

Background Non-sputum diagnostic tools for pulmonary tuberculosis (PTB) are urgently needed, particularly as triage tests in patients unable to produce sputum or with paucibacillary disease. The 6-kDa early secreted antigenic target (ESAT-6), a Mycobacterium tuberculosis–specific secreted antigen, represents a pathogen-derived blood biomarker. We evaluated whether circulating ESAT-6 levels can discriminate PTB and reflect the tuberculosis infection spectrum, with a focus on its potential use as a blood-based triage test in clinical settings where sputum-based diagnostics are limited or delayed. Methods In this case–control study, plasma ESAT-6 concentrations were quantified using a validated quantitative immunoassay, in triplicate. Mean values were used for analysis to minimize intra-assay variability. Study populations were PTB group and control groups comprising nontuberculous mycobacterial lung disease, lung cancer, TB contacts with latent TB infection (LTBI) and without LTBI (non-LTBI), and healthy controls. Diagnostic performance for PTB was evaluated using receiver operating characteristic (ROC) analysis. Optimal cutoff values were determined to assess sensitivity and specificity. Associations between ESAT-6 levels and PTB were examined using multivariable logistic regression. Results Plasma ESAT-6 levels were significantly higher in PTB (n=83; median [IQR], 113.6 [104.3–122.0] ng/mL) than in all non-PTB control groups (combined n=130) (all p< 0.001). A stepwise increase in ESAT-6 concentrations was observed across the TB infection spectrum, with the highest levels in PTB, intermediate levels in LTBI (73.0 [64.8–86.2] ng/mL), and the lowest levels in non-LTBI TB contacts (49.8 [39.0–63.3] ng/mL) (all inter-group p<0.001). ESAT-6 demonstrated excellent discriminative performance for PTB (area under the ROC curve [AUC], 0.976; 95% CI, 0.960–0.992), exceeding that of blood monocyte-to-lymphocyte ratio (AUC, 0.656; 95% CI, 0.573–0.739) and C-reactive protein (AUC, 0.683; 95% CI, 0.595–0.772), and remained independently associated with PTB after adjustment for clinical cofactors. Using an optimized cutoff of 95.0 ng/mL, ESAT-6 achieved a sensitivity of 95.2% and a specificity of 90.8%. Diagnostic performance of ESAT-6 remained robust across clinically relevant subgroups, including culture-negative PTB. Conclusion Quantitative blood ESAT-6 levels reflect the TB infection spectrum and show high accuracy for identifying PTB, supporting its potential role as a pathogen-derived, non-sputum blood-based triage biomarker within clinical laboratory–based diagnostic workflows.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers