A-058 Substantial Reduction in Turnaround Time for Carbapenem-Resistant Enterobacteriaceae (CRE) Screening: A Large-Scale Comparison of Automated Rapid PCR versus Culture-Based Methods

Seok Lae Chae, Hyun Young Chi, KyuJam Hwang, Juyoun Shin

Observational · n=3,906

Key points

From the paper's conclusion
  • Conclusion The implementation of rapid PCR for CRE screening significantly reduced turnaround times by an average of 3.5 days compared to culture-based methods.

Abstract

Background Rapid identification of Carbapenem-Resistant Enterobacteriaceae (CRE) is critical for effective infection control, optimizing isolation, bed utilization, and antimicrobial stewardship. Traditional culture-based methods often delay definitive results. We evaluated the operational impact of implementing a rapid, direct-from-specimen PCR assay compared to a conventional culture-based PCR workflow. Methods We performed a retrospective analysis of CRE screening turnaround times (TAT) for 2025 accessions at Samkwang Medical Laboratories. The study compared 3,906 specimens tested using a rapid PCR assay (BD MAX™ Check-Points CPO assay) against 174 specimens tested with a culture-based PCR assay (PANA RealTyper™ Kit). TAT was defined as the interval from specimen accession to result reporting. Differences in TAT distributions were analyzed using the Mann-Whitney U test, and results were stratified into time intervals (=24 h, 24-72 h, and >72 h) to assess clinical relevance. Results The rapid PCR method demonstrated a drastic reduction in reporting time. The median TAT for rapid PCR was 12.3 hours (IQR: 10.8 – 35.1 h), significantly shorter than the 95.2 hours (IQR: 71.2 – 118.4 h) observed for the culture-based method (p < 0.001). This represents a median time saving of approximately 83 hours (3.5 days) per test. Notably, the majority of rapid PCR results (95.0%, 3,711/3,906) were reported within 24 hours, whereas culture-based PCR required significantly longer processing times, with most results falling into the >72 h category. Conclusion The implementation of rapid PCR for CRE screening significantly reduced turnaround times by an average of 3.5 days compared to culture-based methods. This accelerated reporting capability facilitates prompt isolation decisions and timely therapeutic interventions, thereby enhancing overall infection control efficacy and hospital workflow efficiency.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers