A-046 A novel cardiac troponin assay circumvents positive and negative macrotroponin interference

Saara Wittfooth, Sara Simonen, Selma Salonen, Tuija Vasankari, K E Juhani Airaksinen

Key points

From the paper's conclusion
  • Thus, negative interference due to the presence of cTnAAb and macrotroponin formation was more severe in Elecsys hs-cTnT and Atellica hs-cTnI assays than in the novel long cTn-IT assay.

Abstract

Background Macrotroponin is formed when cardiac troponin-specific autoantibodies (cTnAAb) bind to cardiac troponin (cTn) molecules in the circulation. Macrotroponin can cause elevated cTn levels even in the absence of myocardial injury due to the slow clearance of the large macrotroponin complexes. The presence of cTnAAb and macrotroponin formation may also cause falsely low cTn results, if the autoantibodies target the same epitopes as the cTn assay antibodies. The aim of this study was to develop a cTn immunoassay that avoids macrotroponin interference. Methods A novel immunoassay was designed to detect troponin molecules containing long forms of cardiac troponin T (cTnT) and cardiac troponin I (cTnI) in a complex (long cTn-IT), i.e. any troponin complexes containing cTnT and cTnI in forms where the C-terminal parts remain attached to the central parts. Upconverting luminescence particles were used as assay labels to provide high signals without autofluorescence. The analytical performance of the assay was evaluated by determining the limit of blank (LoB) and the limit of detection (LoD) and by investigating linearity. Lithium-heparin plasma samples from cTnAAb-positive (n=23) and cTnAAb-negative (n=68) apparently healthy individuals were measured with the developed assay, a high-sensitivity (hs) cTnI assay (Atellica, Siemens Healthineers) and a hs-cTnT assay (Elecsys 5th gen, Roche Diagnostics) in their original state and after the addition of 200 ng/L of human endogenous troponin ITC complex. Mann-Whitney U-test was used to compare the median [25th-75th percentile] values between cTnAAb-positive and cTnAAb-negative groups. Results The novel long cTn-IT assay had LoB of 0.2 ng/L and LoD of 0.6 ng/L and the response was linear up to 2000 ng/L. In plasma samples of apparently healthy individuals the long cTn-IT values were similar for cTnAAb-positive and cTnAAb-negative individuals (0.4 [0.2-1.1] ng/L vs. 0.4 [0.2-0.5] ng/L, p=0.172). While for Elecsys hs-cTnT assay the values were also similar (4.7 [3.1-6.1] ng/L vs. 5.4 [3.8-8.1] ng/L, p=0.203), for Atellica hs-cTnI assay the values were significantly higher for cTnAAb-positive individuals (6.4 [2.5-21.9] ng/L vs. 2.5 [2.5-4.5] ng/L, p<0.001) implying positive macrotroponin interference. When the recovery of the added troponin ITC complex in the samples of cTnAAb-positive individuals was evaluated against the median recovery in the samples of cTnAAb-negative individuals measured with the same assay, the recoveries in cTnAAb-positive individuals were 90% [75%-105%] for long cTn-IT assay, 82% [79%-88%] for Elecsys hs-cTnT assay and 53% [46%-62%] for Atellica hs-cTnI assay. Thus, negative interference due to the presence of cTnAAb and macrotroponin formation was more severe in Elecsys hs-cTnT and Atellica hs-cTnI assays than in the novel long cTn-IT assay. Conclusion Positive and negative macrotroponin interference can significantly affect the performance of cTn assays in cTnAAb-positive individuals. A novel long cTn-IT assay can circumvent these interferences.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers