Brain communications

Transformer-based EEG source imaging localizes pathological high-frequency oscillations in focal epilepsy.

Jesse Rong, Zhengxiang Cai, Colton Gonsisko, Boney Joseph, Gregory A Worrell, Bin He

Department of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, PA, USA. · Department of Neurology, Mayo Clinic, Rochester, MN, USA.

Key points

From the paper's conclusion
  • These results demonstrate that TH-DeepSIF provides a data-driven framework for noninvasive high-frequency oscillation source imaging with improved anatomical specificity and support the use of pathological high-frequency oscillations as informative biomarkers for epileptogenic zone localization.

Abstract

High-frequency oscillations are specific biomarkers of the epileptogenic zone, yet their non-invasive localization from scalp EEG remains challenging due to their brief duration, low amplitude and poor signal-to-noise ratio. Here, we introduce a transformer-based high-frequency oscillation deep source-imaging framework (TH-DeepSIF) trained on biologically realistic neural mass model simulations for non-invasive high-frequency oscillation source imaging. The model was evaluated in simulated single- and dual-source scenarios, where it recovered both the spatial location and temporal dynamics of high-frequency oscillation generators under increasing spatiotemporal complexity. We further validated TH-DeepSIF in 20 patients with drug-resistant epilepsy by comparing reconstructed high-frequency oscillation sources with surgical resection regions. TH-DeepSIF achieved accurate localization and waveform reconstruction in simulations, demonstrating low localization error and strong temporal correspondence with ground truth. In clinical data, pathological high-frequency oscillations (spike ripples) showed strong agreement with resection regions, with a median localization error of 10.9 mm and specificity of 0.883. In a subset of six patients with intracranial EEG, pathological high-frequency oscillation source estimates were spatially close to the seizure onset zone (median localization error: 2.41 mm). Compared with all detected high-frequency oscillations, imaging based on pathological high-frequency oscillations yielded significantly improved spatial correspondence and performance across multiple metrics. Reconstructed source activity was also temporally aligned with both scalp high-frequency oscillation bursts and associated spike deflections. These results demonstrate that TH-DeepSIF provides a data-driven framework for non-invasive high-frequency oscillation source imaging with improved anatomical specificity and support the use of pathological high-frequency oscillations as informative biomarkers for epileptogenic zone localization.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Transformer-based EEG source imaging localizes pathological high-frequency oscillations in focal epilepsy — Science Skim