Automated triage to a virtual lung nodule clinic using veye lung nodule volumetry provides a cost saving compared to standard care.
Giles Dixon, Vruti Dattani, Vidan Masani, Pia Charters, Mary Jordan, Jonathan C L Rodrigues
Department of Respiratory Medicine, Royal United Hospitals Bath NHS Foundation Trust, Bath, BA13NG, United Kingdom. · Department of Radiology, Royal United Hospitals Bath NHS Foundation Trust, Bath, BA13NG, United Kingdom.
Key points
From the paper's conclusion- Approximately 10% of thoracic CT scans contained errors in pulmonary nodule reporting. Cost-saving triage pathways combining non-specialist reporting with automated nodule assessment appear feasible and warrant prospective real-world validation.
Abstract
OBJECTIVES: Pulmonary nodules are frequently identified on thoracic CT imaging, with management guided by established clinical pathways. Thoracic CT scans are reported by both specialist and general radiologists. This study evaluated discordance in pulmonary nodule identification and management between general and specialist radiologists and modeled automated triage to a virtual nodule clinic (VNC). METHODS: All CT scans, including the thorax, performed over a 1-week period at a single UK center in March 2022 were identified and original reports reviewed. Oncology follow-up scans were excluded. Reports were categorized and compared with an independent second expert radiologist review. VNC triage pathways were modeled to select patients for second review by an expert radiologist. The pathways used combinations of original radiologist reports and automated nodule assessment (DeepHealth Ltd) to trigger VNC review. The cost implications of each pathway were calculated. RESULTS: Among 243 CT scans, 98 (40%) original reports identified a pulmonary nodule. Expert review identified incorrect recommendations in 24/243 (10%) cases. Errors were significantly more frequent in reports issued by general radiologists compared with specialist thoracic radiologists (χ² ∼ 11.0, df = 2, P < .05). VNC triage pathways that selected cases for secondary review when automated nodule assessment failed to identify a nodule that was identified by the reporting radiologist resulted in the greatest cost savings per corrected nodule. CONCLUSION: Approximately 10% of thoracic CT scans contained errors in pulmonary nodule reporting. Cost-saving triage pathways combining non-specialist reporting with automated nodule assessment appear feasible and warrant prospective real-world validation. ADVANCES IN KNOWLEDGE: This study demonstrates theoretical clinical implementation of semi-automated triage to a virtual nodule clinic and provides an evidence base for prospective study.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- PINPOINT: Integrating Computer Assisted Detection and Virtual Nodule Clinics for Early Lung Cancer Detection in Routine Practice, A Pilot Study.Clinical lung cancer · 2026
- Benchmarking of AI and Radiologists for Indeterminate Lung Nodule Malignancy Risk Estimation at Screening CT: The LUNA25 ChallengeRadiology Artificial Intelligence · 2026
- Correctly Parsed, Wrong Lesion: Where Target Mix-Ups Arise When AI Binds Measurement Requests to Lung CT Nodules—A Staged, Hypothesis-Generating EvaluationAI · 2026
- Role of computer-aided detection (CAD) in detection of pulmonary nodules in computed tomography of the chestThe Egyptian Journal of Radiology and Nuclear Medicine · 2026
- Integration of closed-loop fully-automated AI model with clinician assessment for lung nodule stratification: A multi-reader study.Respiratory investigation · 2026
- Impact of Commercial Artificial Intelligence on Radiologist Reading Time for Pulmonary Nodule Evaluation at Chest CT.Radiology · 2026