Diagnostic Accuracy and Procedural Efficiency of ACR TI-RADS, EU-TIRADS, and K-TIRADS in ≤ 10 mm Thyroid Nodules Using Bethesda Cytology: A Cohort of 998 Nodules.
Mustafa Bilgili, Sinan Karatoprak, Oğuz Aslan, Gamze Türk, Ebru Akay
Department of Radiology, Kayseri City Training and Research Hospital, Kayseri, Turkey. · Department of Pathology, Kayseri City Training and Research Hospital, Kayseri, Turkey.
Key points
From the paper's conclusion- In ≤ 10 mm nodules, the three systems demonstrated distinct diagnostic and classification profiles under a harmonized TR4-5 threshold, with different trade-offs between sensitivity and specificity.
Abstract
OBJECTIVES: To compare the diagnostic performance and procedural efficiency of American College of Radiology Thyroid Imaging Reporting and Data System (ACR TI-RADS), European Thyroid Imaging Reporting and Data System (EU-TIRADS), and Korean Thyroid Imaging Reporting and Data System (K-TIRADS) in ≤ 10 mm nodules using Bethesda cytology as the reference standard. METHODS: This retrospective study included 998 nodules ≤10 mm undergoing ultrasound-guided fine-needle aspiration biopsy (FNAB). Primary analyses included Bethesda II (negative) and Bethesda V-VI (positive) nodules excluding Bethesda I/III/IV, yielding 604 nodules (540 negative; 64 positive). Categories 1-3 were considered low risk and 4-5 high risk under a harmonized threshold Diagnostic performance and classification patterns were compared. RESULTS: K-TIRADS showed the numerically highest sensitivity (93.8%) and negative predictive value (NPV) (97.9%), although sensitivity did not differ significantly between systems, with lower specificity (35.4%) and accuracy (41.6%).EU-TIRADS showed intermediate performans (sensitivity 68.8%, specificity 73.7%, accuracy 73.2%). ACR TI-RADS achieved the highest specificity (83.3%) and accuracy (81.0%) with lower sensitivity (60.9%). Low-risk classification rates were 78.6% (ACR), 69.2% (EU), and 32.3% (K) of nodules; false-positive high-risk classifications among Bethesda II nodules were 16.7%, 26.3%, and 64.6%, respectively. CONCLUSION: In ≤ 10 mm nodules, the three systems demonstrated distinct diagnostic and classification profiles under a harmonized TR4-5 threshold, with different trade-offs between sensitivity and specificity. ADVANCES IN KNOWLEDGE: Applying a harmonized TR4-5 threshold in ≤ 10 mm nodules reveals substantially differences in classification patterns among the three systems, demonstrating that they are not interchangeable under a uniform risk threshold.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Validation of ACR TI-RADS for Predicting Cytological Outcomes in Thyroid Nodules: A Large FNA Cohort Study.Journal of medical imaging and radiation oncology · 2026
- Comparative Diagnostic Accuracy of the American College of Radiology Thyroid Imaging Reporting and Data System (ACR TI-RADS) and the European Thyroid Imaging and Reporting Data System (EU-TIRADS) for Thyroid Nodule Malignancy: A Systematic Review.Cureus · 2026
- Correlation between ultrasound findings of thyroid imaging reporting and data system II and III thyroid nodules and fine-needle aspiration resultsEgyptian Journal of Radiology and Nuclear Medicine · 2026
- Diagnostic Performance of Five Societies’ Ultrasound Risk Stratification Systems for Thyroid Malignancy According to Nodule Size: A Comparison Using a Standardized Ultrasound LexiconThyroid · 2026
- Diagnostic Performance of ACR TI-RADS, EU-TI-RADS, and Individual Ultrasound Features for Predicting Thyroid Malignancy: A Histopathology-Validated Analysis of Surgically Excised Nodules.Cureus · 2026
- Cyto-Radiological Correlation of Nodular Thyroid Lesions Using the Bethesda and American College of Radiology-Thyroid Imaging Reporting and Data System (ACR TI-RADS) Classification Systems: A Cross-Sectional Study.Cureus · 2026