The British journal of radiology

Diagnostic Accuracy and Procedural Efficiency of ACR TI-RADS, EU-TIRADS, and K-TIRADS in ≤ 10 mm Thyroid Nodules Using Bethesda Cytology: A Cohort of 998 Nodules.

Mustafa Bilgili, Sinan Karatoprak, Oğuz Aslan, Gamze Türk, Ebru Akay

Department of Radiology, Kayseri City Training and Research Hospital, Kayseri, Turkey. · Department of Pathology, Kayseri City Training and Research Hospital, Kayseri, Turkey.

Observational

Key points

From the paper's conclusion
  • In ≤ 10 mm nodules, the three systems demonstrated distinct diagnostic and classification profiles under a harmonized TR4-5 threshold, with different trade-offs between sensitivity and specificity.

Abstract

OBJECTIVES: To compare the diagnostic performance and procedural efficiency of American College of Radiology Thyroid Imaging Reporting and Data System (ACR TI-RADS), European Thyroid Imaging Reporting and Data System (EU-TIRADS), and Korean Thyroid Imaging Reporting and Data System (K-TIRADS) in ≤ 10 mm nodules using Bethesda cytology as the reference standard. METHODS: This retrospective study included 998 nodules ≤10 mm undergoing ultrasound-guided fine-needle aspiration biopsy (FNAB). Primary analyses included Bethesda II (negative) and Bethesda V-VI (positive) nodules excluding Bethesda I/III/IV, yielding 604 nodules (540 negative; 64 positive). Categories 1-3 were considered low risk and 4-5 high risk under a harmonized threshold Diagnostic performance and classification patterns were compared. RESULTS: K-TIRADS showed the numerically highest sensitivity (93.8%) and negative predictive value (NPV) (97.9%), although sensitivity did not differ significantly between systems, with lower specificity (35.4%) and accuracy (41.6%).EU-TIRADS showed intermediate performans (sensitivity 68.8%, specificity 73.7%, accuracy 73.2%). ACR TI-RADS achieved the highest specificity (83.3%) and accuracy (81.0%) with lower sensitivity (60.9%). Low-risk classification rates were 78.6% (ACR), 69.2% (EU), and 32.3% (K) of nodules; false-positive high-risk classifications among Bethesda II nodules were 16.7%, 26.3%, and 64.6%, respectively. CONCLUSION: In ≤ 10 mm nodules, the three systems demonstrated distinct diagnostic and classification profiles under a harmonized TR4-5 threshold, with different trade-offs between sensitivity and specificity. ADVANCES IN KNOWLEDGE: Applying a harmonized TR4-5 threshold in ≤ 10 mm nodules reveals substantially differences in classification patterns among the three systems, demonstrating that they are not interchangeable under a uniform risk threshold.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Diagnostic Accuracy and Procedural Efficiency of ACR TI-RADS, EU-TIRADS, and K-TIRADS in ≤ 10 mm Thyroid Nodules Using Bethesda Cytology: A Cohort of 998 Nodules — Science Skim