From Shadows to Signals: Exploring the Strengths and Limitations of AI in Breast Cancer Lesion Detection on Screening Mammograms Compared to Radiologists and Radiology Trainees
Phuong D (Yun) Trieu, Zhengqiang Jiang, Seyedamir Tavakoli Taba, Minyan Zeng, Dania Abu Awwad, Melissa L. Barron, Sarah J Lewis
The University of Sydney · Camden and Campbelltown Hospitals
Key points
From the paper's conclusion- AI demonstrated superior case-level accuracy compared with radiologists and trainees, but limitations in localising specific lesion types, supporting its role as an adjunct to human readers in screening and training.
Abstract
OBJECTIVES: Breast cancer screening with mammography reduces mortality, but interpretation errors persist. While artificial intelligence (AI) shows promise, most studies focus on case-level accuracy and overlook lesion-level performance. This study evaluated the AI (GMIC+CLAHE) model against radiologists and radiology trainees, considering breast density and lesion characteristics. METHODS: Nine BREAST test sets of screening digital mammograms (540 cases:179 cancer, 361 normal) were analysed. AI performance was compared with 17 radiologists and 26 trainees. Case- and lesion-level performance were assessed across breast density, lesion type, and size. AI malignancy scores were dichotomised using Youden's index. Sensitivity, specificity, ROC AUC, lesion localisation, and odds ratios (ORs) were calculated. RESULTS: AI achieved higher case-level AUC (0.974) than radiologists (0.82±0.06;P=0.01) and trainees (0.74±0.05;P<0.0001) across breast densities. At lesion level, AI matched radiologists and outperformed trainees (OR = 1.6;P=0.03), with lesion sensitivities of 66.3% (AI), 67.0% (radiologists), and 55.0% (trainees). AI also outperformed trainees in detecting mixed-type lesions (75%-vs-55%;OR=2.4) and small lesions ≤15 mm (65.7%-vs-55%;OR=1.6). Architectural distortion had the highest miss rate (43.8%) whereas mixed-type lesions demonstrated the lowest miss rate (25.0%) by AI. CONCLUSION: AI demonstrated superior case-level accuracy compared with radiologists and trainees, but limitations in localising specific lesion types, supporting its role as an adjunct to human readers in screening and training. ADVANCES IN KNOWLEDGE: This study integrates case-and-lesion-level evaluation in different case characteristics, identifying key strengths and limitations for clinical implementation. Despite superior case-level accuracy, variability in lesion localisation across cancer types and sizes highlights important considerations for its integration into screening services.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Diagnostic Performance and Concordance of a BI-RADS-Output AI System in Mammography: A Retrospective Study of Radiologists-AI Collaboration.Journal of imaging informatics in medicine · 2026
- From Density to Biopsy Decisions and Malignancy Prediction: A Benchmark Study of Multimodal Large Language Models Against Radiologists in Digital and Contrast-Enhanced MammographyarXiv · 2026
- Diagnostic accuracy, fairness and clinical implementation of AI for breast cancer screening: results of multicenter retrospective and prospective technical feasibility studiesNature Cancer · 2026
- Evaluation of artificial intelligence algorithms from Lunit for detection of breast cancer with mammogram in a South-East Asian population.Breast disease · 2026
- Benchmark Evaluation of Vision-Enabled Large Language Models in Mammography: A Case-Control Study.Journal of breast imaging · 2026
- Ten Years of Artificial Intelligence in Screening Mammography: A Systematic Review and Meta-Analysis of Diagnostic Accuracy and Clinical Implementation (Literature Published 2015-2025).Diagnostics (Basel, Switzerland) · 2026