British Journal of Dermatology

DS22 The impact of sterile vs. nonsterile gloves on surgical-site infection rates following minor procedures in a tertiary dermatology centre

Olivia Kuo, Khin Yadanar Kyaw, Raye Cases, Zoe C Venables, Ava Lee

Key points

From the paper's conclusion
  • Our results demonstrate that use of nonsterile gloves for minor dermatological procedures, when appropriately stored and with ongoing strict hand hygiene and antiseptic nontouch technique, are a safe alternative to sterile gloves.

Abstract

The British Society for Dermatological Surgery sustainability guidance recommends the use of nonsterile gloves for diagnostic biopsies and curettage. Despite this, sterile gloves remain a common standard practice for minor dermatological procedures, with financial, environmental and workflow implications. We assessed the rates of surgical-site infection (SSI) following minor dermatology procedures with sterile vs. nonsterile glove use. Sterile gloves were standard of care for all patients undergoing minor procedures (punch biopsy, shave excision and curettage) in a tertiary dermatology department until 20 November 2025. Six weeks of baseline data for sterile glove use were collected prior to this date, and data on use of nonsterile gloves were collected for 6 weeks following this date. Data collected included patient age, procedure type and site, patient risk factors (immunosuppression, diabetes, anticoagulation or antiplatelet use, impaired mental capacity) and periprocedural antibiotic treatment. Patients were contacted 7–30 days after the procedure and SSI was determined according to the UK Health Security Agency definition for superficial incisional infection. MedCalc software was used to perform χ2-tests to assess differences in proportions of infections in the sterile vs. nonsterile cohorts. In total, 185 procedures in 148 patients were undertaken with sterile gloves. SSI occurred in 4.9% (9 of 185) of wounds, and 1.6% (3 of 185) of wounds were treated with oral antibiotics but did not meet SSI criteria. Overall, 203 procedures were performed in 169 patients using nonsterile gloves. Of these wounds, 2.0% (4 of 203, P = 0.11) developed SSI and 2.0% (4 of 203, P = 0.80) were treated with topical or oral antibiotics but did not meet SSI criteria. No significant difference was found between the two cohorts, and surprisingly a higher proportion of SSIs occurred in the cohort where sterile gloves were used, perhaps due to observer bias or small numbers. Our results demonstrate that use of nonsterile gloves for minor dermatological procedures, when appropriately stored and with ongoing strict hand hygiene and antiseptic nontouch technique, are a safe alternative to sterile gloves.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

DS22 The impact of sterile vs. nonsterile gloves on surgical-site infection rates following minor procedures in a tertiary dermatology centre — Science Skim