A reproducible deep learning pipeline for collagen quantification in cardiac histology, benchmarked against colour deconvolution and inter-observer agreement.
Benjamin Brew, Kamalan Jeevaratnam, Ayman M Ibrahim
School of Computer Science and Electronic Engineering, University of Surrey, Guildford, GU2 7XH, United Kingdom. · Faculty of Health and Medical Sciences, University of Surrey, Guildford, GU2 7AL, United Kingdom.
Key points
From the paper's conclusion- The pipeline provides a reproducible approach to cardiac collagen quantification, while the observer study highlights annotation variability as an important consideration in performance assessment.
Abstract
Collagen area fraction is a standard histological measure of cardiac interstitial fibrosis, but is usually measured using colour thresholding and requires close image-by-image monitoring, which depends on the operator and cannot separate collagen from similarly coloured muscle. We describe an open, reproducible deep learning pipeline for collagen segmentation in mouse heart sections and test it against a calibrated colour-deconvolution baseline and human annotators. Seventy Masson's trichrome fields from 29 mice were traced under a written protocol and partitioned by animal. On eight mice withheld from training and validation, six segmentation architectures reached a mean Dice of 0.787-0.826 against 0.397 for the baseline, which detected most collagen but also included stained muscle. Predicted area fraction tracked the manual reference closely (correlation 0.960-0.989). Mean pairwise Dice between three annotators was 0.846. Against two-observer consensus masks, U-Net++ achieved a mean Dice of 0.795 compared with 0.829 for the observers; this exploratory comparison does not establish equivalence. Three topology-aware objectives, one proposed here, lowered Dice in every test animal. A self-configuring nnU-Net, without hyperparameter search, gave the highest Dice (0.838 over three runs) but did not exceed the agreement between the reference annotator and the closest second annotator (0.841). On picrosirius red, trichrome U-Net++ labelled pale background instead of red-stained collagen, while one retrained on that stain reached 0.855 on perivascular and 0.704 on interstitial fields. The pipeline provides a reproducible approach to cardiac collagen quantification, while the observer study highlights annotation variability as an important consideration in performance assessment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Automated Nucleus Segmentation in Histology Images: An Attention U-Net Approach with Comprehensive Preprocessing and Inference PipelinesarXiv · 2026
- A comparative deep learning approach using foundation models for identification of acute cellular rejection in endomyocardial biopsies of heart transplant recipientsEuropean Heart Journal · 2026
- BigpictureQC: multi-stain, multi-species artifact segmentation for whole-slide quality controlBMC Medicine · 2026
- Reliable Benchmarking of Artifact Detection in Computational Pathology: A Reproducibility and Uncertainty AnalysisarXiv · 2026
- Beyond model accuracy: uncertainty-driven quality control for population-scale CMR segmentationEuropean Heart Journal · 2026
- Towards Reliable AI-Based Histological Staining: A Systematic Study of Scaling and Uncertainty in Unpaired Generative ModelsarXiv · 2026