Improving Lipid Identification and Quantification: Chromatogram Deconvolution for LC-MS/MS Workflows.
Felix Niedermaier, Denise Wolrab-Frühauf, Robert Ahrends, Dominik Kopczynski
Department of Analytical Chemistry, Faculty of Chemistry, University of Vienna, Währinger Str. 38, 1090, Vienna, Austria.
Key points
From the paper's conclusion- Here, we introduce an algorithm that deconvolutes chimeric MS/MS spectra and chromatograms by exploiting their temporal correlation with associated precursor chromatographic profiles, independent of elution peak shape. Using simulated and real experimental lipidomics data, we demonstrate that this approach substantially improves lipid fragment assignment, reduces false-positive identifications, and enables more reliable fragment-level quantification, leading to more robust downstream statistical analyses and biological interpretations.
Abstract
MOTIVATION: Lipidomics relies on mass spectrometry-based workflows to identify and quantify complex lipid species. Due to the modular architecture of lipids, including headgroups, backbones, and fatty acyl chains, distinct precursor ions often produce isobaric or identical fragment ions. This problem is amplified in data-independent acquisition (DIA), where wide isolation windows (e.g., 25 Da) allow co-eluting precursors with different m/z values to generate highly chimeric MS/MS spectra. Consequently, fragments originating from multiple precursors, including isobars, isomers, and lipid-class-specific ions, are merged into a single MS/MS spectrum. Current lipid identification strategies often process such chimeric spectra in an uncontrolled manner, assigning them to one or more candidate lipids, thereby increasing false-positive identifications. RESULTS: Here, we introduce an algorithm that deconvolutes chimeric MS/MS spectra and chromatograms by exploiting their temporal correlation with associated precursor chromatographic profiles, independent of elution peak shape. Using simulated and real experimental lipidomics data, we demonstrate that this approach substantially improves lipid fragment assignment, reduces false-positive identifications, and enables more reliable fragment-level quantification, leading to more robust downstream statistical analyses and biological interpretations. AVAILABILITY AND IMPLEMENTATION: Source code of the software library: GitLab (Apache 2.0 License): https://gitlab.com/computational-multiomics/mixture-model-deconvolution; Data: Zenodo (Apache 2.0 License): https://doi.org/10.5281/zenodo.21218594. SUPPLEMENTARY INFORMATION: Supplementary data are available at Bioinformatics online.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Resolving Spectral Complexity in 4D Lipidomics Using a Two-Dimensional Deconvolution Framework.Angewandte Chemie (International ed. in English) · 2026
- LipidRT: leveraging retention time coherence for robust lipid annotation in reversed-phase LC-MS-based lipidomicsbioRxiv · 2026
- LC-MS/MS-Based Untargeted Lipidomics Using MS-DIAL.Methods in molecular biology (Clifton, N.J.) · 2026
- A Practical Guide to Dereplication in Natural Products Metabolomics.Journal of natural products · 2026
- MS2-KNN: A Computational Framework Resolving Chimeric Small-Molecule MS/MS Spectra by Latent-Space Neighborhood Decomposition and Scaffold Confidence ScoringAnalytical Chemistry · 2026
- Tissue Heterogeneity‐Driven Parallel Acquisition for High‐Coverage MS/MS Imaging of LipidsAngewandte Chemie International Edition · 2026