Bioinformatics (Oxford, England)

Improving Lipid Identification and Quantification: Chromatogram Deconvolution for LC-MS/MS Workflows.

Felix Niedermaier, Denise Wolrab-Frühauf, Robert Ahrends, Dominik Kopczynski

Department of Analytical Chemistry, Faculty of Chemistry, University of Vienna, Währinger Str. 38, 1090, Vienna, Austria.

Computational

Key points

From the paper's conclusion
  • Here, we introduce an algorithm that deconvolutes chimeric MS/MS spectra and chromatograms by exploiting their temporal correlation with associated precursor chromatographic profiles, independent of elution peak shape. Using simulated and real experimental lipidomics data, we demonstrate that this approach substantially improves lipid fragment assignment, reduces false-positive identifications, and enables more reliable fragment-level quantification, leading to more robust downstream statistical analyses and biological interpretations.

Abstract

MOTIVATION: Lipidomics relies on mass spectrometry-based workflows to identify and quantify complex lipid species. Due to the modular architecture of lipids, including headgroups, backbones, and fatty acyl chains, distinct precursor ions often produce isobaric or identical fragment ions. This problem is amplified in data-independent acquisition (DIA), where wide isolation windows (e.g., 25 Da) allow co-eluting precursors with different m/z values to generate highly chimeric MS/MS spectra. Consequently, fragments originating from multiple precursors, including isobars, isomers, and lipid-class-specific ions, are merged into a single MS/MS spectrum. Current lipid identification strategies often process such chimeric spectra in an uncontrolled manner, assigning them to one or more candidate lipids, thereby increasing false-positive identifications. RESULTS: Here, we introduce an algorithm that deconvolutes chimeric MS/MS spectra and chromatograms by exploiting their temporal correlation with associated precursor chromatographic profiles, independent of elution peak shape. Using simulated and real experimental lipidomics data, we demonstrate that this approach substantially improves lipid fragment assignment, reduces false-positive identifications, and enables more reliable fragment-level quantification, leading to more robust downstream statistical analyses and biological interpretations. AVAILABILITY AND IMPLEMENTATION: Source code of the software library: GitLab (Apache 2.0 License): https://gitlab.com/computational-multiomics/mixture-model-deconvolution; Data: Zenodo (Apache 2.0 License): https://doi.org/10.5281/zenodo.21218594. SUPPLEMENTARY INFORMATION: Supplementary data are available at Bioinformatics online.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers