Somatic likelihood tiering: an interpretable post-calling triage protocol for tumor-only whole-exome variant review.
Konrad Stawiski, Sophia C Kamran, Júlia Perera-Bel, Jihyun Lee, Joaquim Bellmunt, Kent W Mouw, Filipe L F De Carvalho
Department of Radiation Oncology, Dana-Farber Cancer Institute, 450 Brookline Ave., 02215 Boston, MA, United States. · Department of Radiation Oncology, Mass General Brigham, 800 Boylston St., 02199 Boston, MA, United States.
Key points
From the paper's conclusion- Somatic likelihood tiering (SLT) is an interpretable post-calling protocol that ranks Mutect2 calls into four review-priority tiers using population-frequency, germline-quality, cancer-knowledge, PureCN posterior, and clonal-hematopoiesis evidence.
Abstract
Tumor-only whole-exome sequencing (WES) is used when matched normal tissue is unavailable, but one sample can produce thousands of variants. Somatic likelihood tiering (SLT) is an interpretable post-calling protocol that ranks Mutect2 calls into four review-priority tiers using population-frequency, germline-quality, cancer-knowledge, PureCN posterior, and clonal-hematopoiesis evidence. Layer 2 distinguishes common, rare-callable, and unevaluable gnomAD states; missing or unmatchable gnomAD evidence is not positive rarity evidence. On the SEQC2 HCC1395 benchmark, the callability-aware SLT-A row contained 101 calls, 78 truth variants, 77.2% PPV (95% Wilson confidence interval 68.1%-84.3%), and a Number Needed to Review (NNR) of 1.29 (1.19-1.47). The conservative SLT-C catchment retained 352 of 455 truth variants (77.4%, 73.3%-81.0%) and all tiers together retained 430 of 455 truth variants. SNV performance is the primary calibration frame: SLT-C retained 341 of 439 SNV truth variants, whereas indel results were exploratory because only 16 truth indels were available. Clinical cohorts are reported as recall and concordance versus partially dependent matched-normal Mutect2 references, not independent clinical sensitivity. Patient-level bootstrap intervals were principal: HdM-BLCA-1 SLT-A recall was 18.2% (14.0%-23.5%), and LUAD-TW SLT-A recall was 49.1% (26.6%-63.3%) among 32 evaluable patients. The HdM-BLCA-1 median SLT-A queue remained 1277 variants per patient, so SLT reduces first-pass candidate counts but does not measure review time or eliminate FFPE candidate-count burden. SLT provides an auditable tumor-only WES review queue, not a substitute for matched-normal sequencing, independent orthogonal validation, or definitive somatic classification.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- ClairS-TO: a deep-learning method for long-read tumor-only somatic small variant callingNature Communications · 2025
- Scalable subclonal reconstruction of cancer cells in DNA sequencing data using a penalized likelihood modelbioRxiv · 2026
- Somatic haplotype reconstruction and variant recalibration from tumor-only long-read sequencingbioRxiv · 2026
- Advancing Lung Cancer Staging: Integrating IASLC Recommendations and Bioinformatics to Delineate Tumor OriginsJournal of Thoracic Oncology · 2025
- Oncogenicity Variant Interpreter (OncoVI) Supports Harmonized Somatic Variant Interpretation in Precision OncologyJournal of Molecular Diagnostics · 2026
- Challenges of Using Circulating Tumour DNA: Insights from Advanced Prostate Cancer.European urology · 2026