Implant Survival and Autologous Breast Augmentation in Rupture Management.
Tung Dinh Nguyen
Key points
From the paper's conclusion- Hybrid autologous breast augmentation using a TRAM flap and fat grafting is a reliable and aesthetically satisfying alternative to reimplantation. MRI facilitates accurate rupture diagnosis and postoperative volumetric monitoring. This technique also yields abdominal contouring benefits and reduced long-term costs, making it an attractive option for selected patients.
Abstract
BACKGROUND: Silicone breast implants remain a mainstay of aesthetic surgery; however, long-term rupture remains a significant complication. MRI offers superior sensitivity for detecting silent ruptures. In patients declining reimplantation, autologous breast augmentation using a pedicled transverse rectus abdominis myocutaneous (TRAM) flap combined with fat grafting presents a natural, durable alternative. OBJECTIVES: The purpose of this study was to evaluate long-term implant survival and the outcomes of hybrid autologous augmentation using pedicled TRAM flap and fat grafting following explantation for rupture. METHODS: A retrospective review was conducted on 150 female patients with 179 ruptured implants (June 2022-September 2024). Implant rupture was confirmed through 3T MRI. Implant longevity was analyzed using Kaplan-Meier survival. A subgroup of 41 patients underwent autologous reconstruction using a modified pedicled TRAM flap plus fat grafting. Intraoperative flap volume was calculated using a geometric model for truncated pyramids. Fat retention was quantified through MRI at 6 to 12 months. Patient-reported satisfaction was assessed using the BREAST-Q Postoperative Augmentation Module. RESULTS: MRI demonstrated linguine (25.1%), teardrop (15.6%), and combined rupture signs. Kaplan-Meier analysis showed a 20-year implant survival rate of 83%. In the autologous group (n = 41), the average intraoperative volume was 328.5 cc, with 83.0% fat retention on follow-up MRI. The mean BREAST-Q satisfaction score was 62.7, positively correlating with volume retention (r = 0.317, P = .043). CONCLUSIONS: Hybrid autologous breast augmentation using a TRAM flap and fat grafting is a reliable and aesthetically satisfying alternative to reimplantation. MRI facilitates accurate rupture diagnosis and postoperative volumetric monitoring. This technique also yields abdominal contouring benefits and reduced long-term costs, making it an attractive option for selected patients.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Autologous Fat Grafting for Breast Augmentation and Breast Remodeling: A Systematic Review and Meta-analysis of Complications, Radiologic Outcomes, Graft Retention, and Patient-Reported Satisfaction.Aesthetic surgery journal · 2026
- SVF-Enriched Versus Standard Fat Grafting for Breast Reconstruction and Augmentation: A Prospective Multicenter Comparative Randomized Study.Aesthetic surgery journal · 2026
- Evaluation of the efficacy and safety of breast augmentation using implants combined with autologous fat grafting: a retrospective study of 219 cases.Gland surgery · 2026
- Multicentric Retrospective Study on Smooth Opaque Silicone Breast Implants: Over-2-Year Outcomes in Primary Augmentation and Revision Surgery.Medicina (Kaunas, Lithuania) · 2026
- Outcomes of postmastectomy radiotherapy in immediate autologous versus implant-based breast reconstruction: a multi-institutional cohort study.Breast cancer research and treatment · 2026
- Implant-Based Versus Autologous Reconstruction After Salvage Mastectomy for Ipsilateral Breast Tumor Recurrence in the Previously Irradiated Breast: A Consecutive Institutional Series and a Proposed Autologous-First Algorithm.Cancers · 2026