Functional Performance, Subject-body Perception, and Safety Following Multi-muscle Electromuscular Stimulation: A Randomized Controlled Study.
Kiya Movassaghi, Niloo Marashi, Shlomit Mann, Ruthie Amir
Oregon Health & Science University, Portland, OR, USA. · Private practice in Eugene, OR, USA.
Key points
From the paper's conclusion- Treatment with PlyoPulse technology was associated with measurable improvements in functional performance, enhanced body self perception and a favorable safety profile. The findings suggest that stimulation patterns incorporating a programmable synchronized multi muscles activation may better enhance coordinated neuromuscular recruitment consistent with exercise physiology.
Abstract
BACKGROUND: Electromuscular stimulation (EMS) and high-intensity focused electromagnetic technologies are widely used for non-invasive muscle strengthening and body contouring. Most available EMS devices induce repetitive contractions of isolated muscle groups resulting in increased muscle thickness and improved aesthetic outcome. However, the current literature is lacking evidence to support functional performance gain following EMS treatments. OBJECTIVES: To evaluate functional performance outcomes following treatment with a novel EMS technology. based on synchronized multi-muscle activation and regulated contraction duty cycles. METHODS: Thirty-eight healthy adult subjects were equally randomized to treatment and blank control cohorts. The study was conducted between July 2025 and January 2026. The treatment protocol included six weekly sessions targeting abdominal, quadriceps, hamstring, and gluteal muscle groups. Functional performance assays included prone hip extension repetitions to measure gluteus, paced curl-up performance and side plank endurance to measure abdominal muscles and seated quadriceps extension repetitions for measuring quadriceps strength. Subject reported body perception was documented. Outcome measures were performed at baseline, week 5 (pre-last treatment), and week 9 (4 weeks post last treatment). Subjects' performance over time and comparisons between groups were analyzed. RESULTS: The treatment group demonstrated statistically significant gain in repetition-based and endurance-based performance measures compared with baseline and control subjects. Improvements were maintained through the 4-week follow-up. Treated subjects body self perception was improved. The procedure was well tolerated, with low discomfort and no reported adverse events. CONCLUSIONS: Treatment with PlyoPulse technology was associated with measurable improvements in functional performance, enhanced body self perception and a favorable safety profile. The findings suggest that stimulation patterns incorporating a programmable synchronized multi muscles activation may better enhance coordinated neuromuscular recruitment consistent with exercise physiology.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- An interactive EMG-EMS system for assisted exercise monitoring: a user-centered evaluation.Medical & biological engineering & computing · 2026
- A Standardized Methodology for EMG-Based Fatigue Assessment during Electrical Muscle StimulationCurrent Directions in Biomedical Engineering · 2026
- Acute Effects of Neuromuscular Electrical Stimulation Priming on Volleyball Spike Performance and Three-Dimensional Kinematics.Journal of visualized experiments : JoVE · 2026
- Effectiveness and safety of electrical muscle stimulation following major abdominal surgery: a systematic review and meta-analysis of clinical and functional outcomesBMC Surgery · 2026
- Effects of Narrow- Vs. Wide-Pulse Neuromuscular Electrical Stimulation Training on Functional Performance.Journal of strength and conditioning research · 2026
- Functional recovery of athletes through rehabilitation training after anterior cruciate ligament reconstruction.Acta of bioengineering and biomechanics · 2026