Archives of Clinical Neuropsychology

B-182: Evaluation of Updated and Prior Stroop Color and Word Test Norms in a Diverse Veteran Older Adult Sample

Melissa A Talamantes, Janice C Marceaux, Kathleen M Bain, Kirstine R Carter, Rebecca C Render

Key points

From the paper's conclusion
  • We compared the application of Stroop Color and Word Test (Stroop) Normative Update (Golden et al., 2022) to previous norms (Golden & Freshwater, 2002; MOANS-Ivnik et al., 1996; MOAANS-Lucas et al., 2005) in a diverse veteran older adult sample.

Abstract

Objective: Evaluation of norms applied to diverse populations supports ethical decision-making in diagnosis and treatment (Bush et al., 2018). We compared the application of Stroop Color and Word Test (Stroop) Normative Update (Golden et al., 2022) to previous norms (Golden & Freshwater, 2002; MOANS-Ivnik et al., 1996; MOAANS-Lucas et al., 2005) in a diverse veteran older adult sample. Method/Data Selection: Veterans who passed performance validity testing and completed Stroop (n=170; M_age=68.1; 50% with neurocognitive disorder) were included. The sample was diverse (54.1% White/Caucasian, 32.9% Hispanic/Latino, 12.9% African American/Black). Logistic regression (LR) and receiver operator characteristic (ROC) analyses examined diagnostic classification accuracy of Stroop Color-Word (CW) and Interference T-scores overall and within subgroups. Results/Data Synthesis: LR models (overall) for Golden-2022 and MOANS CW norms had the highest classification accuracy (71.8%). MOANS LR model was significant (χ2[1]=39.6, p<.001) and explained 28% of the variance (Nagelkerke-R2) in diagnosis (vs. 27% for Golden-2022 norms). For Hispanic/Latino participants, Golden-2022 and MOANS norms correctly classified 73.2%, accounting for 25% and 24% of the variance, respectively; Golden-2022 better classified those with neurocognitive disorders. For African American/Black participants, Golden-2022 correctly classified 72.7% (24% variance explained). Interference ROC analyses (AUC=.50) and LR found low classification accuracy. Specificity for CW/Interference norms was unacceptably low (highest CW=.32; Golden-2002). At best, CW sensitivity levels for T=40 was .68 (Golden-2002). MOAANS had low sensitivity/specificity. Conclusions: While classification accuracy was best with updated, Golden-2022 Stroop-CW norms, Golden-2002 CW had the best sensitivity/specificity, though none achieved adequate specificity for predicting diagnosis broadly. Use of MOAANS norms is not recommended based on findings.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers