Electrical impedance tomography-guided positive end-expiratory pressure and mortality of patients with the acute respiratory distress syndrome: the EITVent randomized clinical trial.
Xueyan Yuan, Ming Zhong, Zhe Li, Ling Sang, Xiaobo Huang, Rui Zhang, Hui Chen, Yuan Gao,
Jiangsu Provincial Key Laboratory of Critical Care Medicine, Department of Critical Care Medicine, Zhongda Hospital, School of Medicine, Southeast University, Nanjing, China. · Department of Critical Care Medicine, Zhongshan Hospital of Fudan University, Shanghai, China.
Key points
From the paper's conclusion- In patients with moderate to severe ARDS, EIT-guided PEEP did not significantly reduce 28-day mortality compared with the lower PEEP/FiO2 table strategy. Due to early termination, the study may have been underpowered to detect a clinically important difference.
Abstract
RATIONALE: Physiological studies showed benefits for bedside setting of personalized positive end-expiratory pressure (PEEP) by electrical impedance tomography (EIT), balancing lung overdistension and collapse. OBJECTIVES: To evaluate whether EIT-guided PEEP improves the clinical outcomes of patients with acute respiratory distress syndrome (ARDS) compared to the lower PEEP/FiO2 table strategy. METHODS: This randomized trial enrolled adult patients with moderate to severe ARDS across five sites in China from February 2022 to June 2023. Participants were randomly assigned to EIT-guided PEEP (collapse-overdistension crossing point value by decremental PEEP trial) or the classical lower PEEP/FiO2 table. The primary outcome was 28-day mortality. MEASUREMENTS AND MAIN RESULTS: The trial was terminated early for futility, based on a pre-planned interim analysis. A total of 190 patients were included and completed follow-up. PEEP levels didn't differ between groups during the first 7 days (difference in marginal means 0.2 [SE 0.1]; P = .187). At 28 days, mortality was 52 patients (55.9%) in the EIT-guided PEEP group and 51 patients (52.6%) in the lower PEEP/FiO2 table group (hazard ratio [HR] 0.96 [95% CI, 0.65-1.41]; P = .821). Ventilator-free days and other secondary clinical and safety outcomes did not differ, either. However, EIT-guided PEEP assigned higher PEEP and decreased mortality in patients with higher lung recruitability, as assessed by the recruitment-inflation ratio method (16 [35.6%] of 45 patients vs 27 [60.0%] of 45 patients; HR 0.49 [95% CI, 0.26-0.91]; P = .024). CONCLUSIONS: In patients with moderate to severe ARDS, EIT-guided PEEP did not significantly reduce 28-day mortality compared with the lower PEEP/FiO2 table strategy. Due to early termination, the study may have been underpowered to detect a clinically important difference. TRIAL REGISTRATION: clinicaltrials.gov NCT05207202.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Electrical impedance tomography-guided individualized ventilation strategy in patients with trauma-related and postoperative acute respiratory distress syndrome.PloS one · 2026
- Regional ventilation at EIT-guided PEEP and mortality in severe ARDS: a prospective observational study.BMC pulmonary medicine · 2026
- The impact of PEEP-guided electrical impedance tomography on oxygenation and respiratory mechanics in moderate-to-severe ARDS: a randomized controlled trialScientific Reports · 2025
- Monitoring of regional ventilation and ventilator-induced lung injury in pediatric acute respiratory distress syndrome (MoVe lupARDS): a study protocol for a randomized controlled trial.Trials · 2026
- Determinants of tidal recruitment/derecruitment assessed by electrical impedance tomography in spontaneously breathing ARDS patientsAmerican Journal of Respiratory and Critical Care Medicine · 2026
- Electrical Impedance Tomography-Guided Synergistic Intervention of Respiratory Muscle Training and Postural Adjustment for Lung Recruitment in Critically Ill Patients With Respiratory Failure.Physiological research · 2026