科研速览 · Science Skim继续刷下去 · Keep skimming →
◆ American Journal of Respiratory and Critical Care Medicine2026-01-05· Medicine

Electrical impedance tomography-guided PEEP and mortality of patients with the acute respiratory distress syndrome: The EITVent randomized clinical trial

Xueyan Yuan, Ming Zhong, Zhe Li, Ling Sang, Xiaobo Huang, Rui Zhang, H. CHEN, Yuan Gao, Yuxian Wang, Zhimin Lin, Sen Lu, Fang Yang, Tao Chen, Lanqi Guo, Xie Jp, Zhanqi Zhao, Yingzi Huang, Yi Yang, Tommaso Mauri, Haibo Qiu, L Liu

原始摘要(英文原文)· Original abstract
RATIONALE: Physiological studies showed benefits for bedside setting of personalized positive end-expiratory pressure (PEEP) by electrical impedance tomography (EIT), balancing lung overdistension and collapse. OBJECTIVES: To evaluate whether EIT-guided PEEP improves the clinical outcomes of patients with acute respiratory distress syndrome (ARDS) compared to the lower PEEP/FiO2 table strategy. METHODS: This randomized trial enrolled adult patients with moderate to severe ARDS across five sites in China from February 2022 to June 2023. Participants were randomly assigned to EIT-guided PEEP (collapse-overdistension crossing point value by decremental PEEP trial) or the classical lower PEEP/FiO2 table. The primary outcome was 28-day mortality. MEASUREMENTS AND MAIN RESULTS: The trial was terminated early for futility, based on a pre-planned interim analysis. A total of 190 patients were included and completed follow-up. PEEP levels didn't differ between groups during the first 7 days (difference in marginal means 0.2 [SE 0.1]; P = .187). At 28 days, mortality was 52 patients (55.9%) in the EIT-guided PEEP group and 51 patients (52.6%) in the lower PEEP/FiO2 table group (hazard ratio [HR] 0.96 [95% CI, 0.65-1.41]; P = .821). Ventilator-free days and other secondary clinical and safety outcomes did not differ, either. However, EIT-guided PEEP assigned higher PEEP and decreased mortality in patients with higher lung recruitability, as assessed by the recruitment-inflation ratio method (16 [35.6%] of 45 patients vs 27 [60.0%] of 45 patients; HR 0.49 [95% CI, 0.26-0.91]; P = .024). CONCLUSIONS: In patients with moderate to severe ARDS, EIT-guided PEEP did not significantly reduce 28-day mortality compared with the lower PEEP/FiO2 table strategy. Due to early termination, the study may have been underpowered to detect a clinically important difference. TRIAL REGISTRATION: clinicaltrials.gov NCT05207202.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Electrical impedance tomography-guided PEEP and mortality of patients with the acute respiratory distress syndrome: The EITVent randomized clinical trial — 科研速览 Science Skim