Publicly visible regulatory timing from US Food and Drug Administration breakpoint updates to automated antimicrobial susceptibility test clearances: a longitudinal database study, 2017-2026.
Zilin Li, Xiaoxiao He
Department of Laboratory Medicine, Xichong County People's Hospital, Nanchong, Sichuan, China. · Institute of Basic Medicine and Forensic Medicine, North Sichuan Medical College, Nanchong, Sichuan, China.
Key points
From the paper's conclusion- We measured publicly visible intervals from US Food and Drug Administration (FDA) breakpoint actions to clearances for established automated AST platforms.
Abstract
OBJECTIVES: Updated antimicrobial susceptibility testing (AST) breakpoints require implementation in laboratory systems, but the timing of device updates across revisions has not been quantified. We measured publicly visible intervals from US Food and Drug Administration (FDA) breakpoint actions to clearances for established automated AST platforms. METHODS: Drug-specific FDA breakpoint actions from January 1, 2017, through August 23, 2026, were linked to 510(k) decision summaries for MicroScan, VITEK 2/VITEK 2 Compact, and BD Phoenix when the public record supported the drug, organism group, platform, and updated breakpoint relationship. Total lag was decomposed into breakpoint-to-receipt submission lag and receipt-to-decision FDA review interval. RESULTS: Eighty-nine FDA notice rows yielded 22 eligible breakpoint events. Among 103 screened decision summaries, 13 clearances supported 18 links; 16 primary links involving 11 unique clearances and 10 events met prespecified criteria. Median total lag was 22.3 months (interquartile range, 9.1-42.0; range, 0.1-59.7), median submission lag was 13.3 months (interquartile range, 5.7-32.8), and the median review interval among unique clearances was 6.9 months (interquartile range, 3.1-7.7). Three submissions were received before the corresponding breakpoint action. No qualifying public link was identified for 12 events, but this cannot establish outdated labeling because cleared change protocols may permit updates without another 510(k). CONCLUSIONS: Public 510(k) records show heterogeneous breakpoint-to-clearance intervals, with a longer prereceipt than review component. A dated, machine-readable registry of breakpoint-related labeling changes would improve transparency, including for updates made without a new 510(k).
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Performance evaluation of antimicrobial susceptibility testing devices across CLSI, EUCAST, ISO, FDA, and EMA frameworks: implications for breakpoint application.Journal of clinical microbiology · 2026
- A comprehensive report on the 1st Swiss-EUCAST Antimicrobial Susceptibility Testing (AST) Meeting.FEMS microbiology letters · 2026
- Race for Speed: Advances in Rapid Antimicrobial Susceptibility Testing across Bacterial and Fungal Pathogens.ACS sensors · 2026
- Rapid Antimicrobial Susceptibility Testing (AST): Overview of New Commercially Available Automated Phenotypic Tools for Minimum Inhibitory Concentration (MIC) DeterminationMicrobiology Research · 2026
- Rapid Phenotypic Antimicrobial Susceptibility Testing and Rapid Molecular Identification with Resistance-Marker Detection for Bloodstream Infections: A Systematic Review with Separate Narrative Syntheses.Medical sciences (Basel, Switzerland) · 2026
- Automated antimicrobial susceptibility testing in gram-negative bacteremia: A comparative study of VITEK® REVEAL™ and BD phoenix™.Diagnostic microbiology and infectious disease · 2026