62 Optimization of Legionella pneumophila Diagnostic Testing in a Large Healthcare System in Southeast Texas

Belkys Sanchez, Randy Olsen, Wesley Long

Observational

Key points

From the paper's conclusion
  • Given that Legionella culture is labor-intensive and has an extremely low positivity rate (0.08% in this study), implementation of the PNE Panel has allowed our institution to discontinue routine Legionella culture and has significantly improved laboratory workflows.

Abstract

Background Legionella pneumophila is an aquatic bacterium and the causative agent of Legionnaire’s disease, an uncommon but clinically significant community‑acquired pneumonia with mortality rates averaging 3 to 10%. Laboratory diagnosis of L. pneumophila presents challenges; isolation of L. pneumophila requires specialized media and extended incubation. Urinary antigen testing is limited to L. pneumophila serogroup 1 and demonstrates reduced sensitivity and specificity, especially in non-critically ill patients. Rapid and accurate diagnostic methods are critical, especially since Legionnaires’ disease cannot be clinically distinguished from other pneumonias and early targeted therapy is essential for high‑risk patients. Methods This study evaluated the clinical performance of the bioMérieux BIOFIRE® Pneumonia (PNE) Panel for detecting L. pneumophila in bronchoalveolar lavage (BAL) specimens, compared with standard‑of‑care (SOC) diagnostics. SOC methods consisted of Legionella culture and L. pneumophila serogroup 1 urinary antigen testing by immunochromatographic assays (Immunoview or BinaxNOW). Two-by-two data tables were used to determine agreement between the PNE Panel and composite results from SOC methods. Positive percent agreement (PPA) and negative percent agreement (NPA) were calculated using GraphPad Prism. Results A total of 3431 BAL specimens tested with the PNE Panel in 2024 and 2025 were included in the study and results retrospectively reviewed. The PNE Panel was positive and agreed with SOC testing results in five out of 9 BAL specimens for a PPA of 55.6%. Compared with SOC methods, the PNE Panel demonstrated an NPA of 99.8% for the detection of L. pneumophila. The PNE Panel detected L. pneumophila in six patients who did not have a corresponding positive culture or urinary antigen. Four patients had not detected L. pneumophila results by the PNE Panel and positive L. pneumophila serotype 1 urinary antigen tests. Review of the medical records indicated that L. pneumophila was considered the etiologic agent of the infection in only two of these cases. Subsequent evaluation of the performance of the Immunoview Streptococcus pneumoniae/L. pneumophila urinary antigen test used in these two cases, showed that only 69% of positive results were confirmed by a second urinary antigen method (BinaxNOW), suggesting that the Immunoview assay is prone to false positive results. Conclusions The PNE Panel showed increased ability to detect L. pneumophila compared to SOC methods and demonstrated excellent NPA. This test has the potential to significantly impact the management of patients with Legionnaire’s disease by enabling rapid targeted therapy. Given that Legionella culture is labor-intensive and has an extremely low positivity rate (0.08% in this study), implementation of the PNE Panel has allowed our institution to discontinue routine Legionella culture and has significantly improved laboratory workflows.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers