  • We performed a retrospective review of granulocyte apheresis collections and transfusions at a large academic medical center (April 2016 –June 2024), to assess hematologic response, safety (adverse transfusion events), and short-term outcomes with high-yield, volume-reduced (VR) GTs.

Abstract

Granulocyte transfusions (GTs) are used in selected neutropenic patients with severe or refractory infections, yet clinical efficacy remains uncertain, in part due to variability in granulocyte dose and product characteristics. We performed a retrospective review of granulocyte apheresis collections and transfusions at a large academic medical center (April 2016 –June 2024), to assess hematologic response, safety (adverse transfusion events), and short-term outcomes with high-yield, volume-reduced (VR) GTs. Clinical outcomes such as infection type, infection resolution, or transfusion-associated benefit were not evaluated. Laboratory outcomes and short-term survival were described. A total of 199 infusions were recorded across 42 patients (28 male, 14 female); however, collection and transfusion data were available for 182 infusions obtained using large-volume processing with post-collection volume reduction. The median granulocyte dose per transfusion was 212.5 × 10⁹/kg (interquartile range [IQR] 179.3–272.3). Pre- and post-transfusion absolute neutrophil counts (ANCs) were collected from clinical records. Post-transfusion ANCs were obtained within 24 hours for most cases and within 48 hours for a minority. Peak ANC within this window was used to calculate ANC increment. Median pre-transfusion ANC was 223.9 cells/µL (IQR 1.7–1235.1). Median post-transfusion ANC was 1428.8 cells/µL (IQR 697.9–3128.0), corresponding to a median ANC increment of ∼1200 cells/µL. 63% of transfusions achieved an increment ≥500 cells/µL and 44% achieved ≥1000 cells/µL. Although our sampling window was broader, the increments were similar in order of magnitude to those in the RING trial, where ANC was assessed within 2.5 hours post-transfusion and increased by ∼1.75 × 10⁹/L (∼1750 cells/ul) for each additional 1 × 10⁹ granulocytes/kg delivered. Febrile nonhemolytic transfusion reactions occurred in 15.9% (29/182) of transfusions, while transfusion-associated circulatory overload (2/182) and transfusion-related acute lung injury (2/182) each occurred in 1.1% of transfusions. Survival analysis at six months after first GT, 22/42 patients (52%) were still alive while 9/42 (21%) died within 28 days. The remaining patients died between 29 days and 3 months, including several within the predefined 42-day endpoint, consistent with the severity and the heterogeneity of this cohort. In this retrospective cohort, high-yield, VR GTs were associated with post-transfusion ANC increments and an acceptable safety profile. These findings support feasibility of this optimized collection approach and underscore the need for prospective studies to better define clinical benefit of this resource-intensive therapy.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers