American Journal of Clinical Pathology

30 Evaluation of Paired Maternal and Neonatal Urine Testing Strategies for Detection of In Utero Drug Exposure

Kimberly Huggler, Mark Zaydman, Bridgit Crews

Key points

From the paper's conclusion
  • We previously demonstrated that direct testing of neonatal urine by liquid chromatography–tandem mass spectrometry (LC–MS/MS) provides sensitivity comparable to meconium for detecting amphetamine, methamphetamine, and cocaine exposure.

Abstract

Background Identification of in utero drug exposure is critical for guiding neonatal care but can be challenging. Laboratory testing provides objective evidence, and meconium testing is generally considered the reference method due to its longer detection window. However, meconium passage may be delayed and testing is typically performed at specialized laboratories, resulting in prolonged turnaround times that limit clinical utility. Immunoassay (IA)–based urine drug testing is a rapid alternative but was optimized for drug detection in adults and is susceptible to false-positives. We previously demonstrated that direct testing of neonatal urine by liquid chromatography–tandem mass spectrometry (LC–MS/MS) provides sensitivity comparable to meconium for detecting amphetamine, methamphetamine, and cocaine exposure. In this study, we evaluated whether combined maternal and neonatal urine testing improves detection compared with neonatal testing alone and compared IA-based screening to direct LC–MS/MS testing. Design We analyzed paired neonatal urine, meconium, and maternal urine collected between January 2021 and December 2022 from two independent cohorts (cohort 1, n = 891; cohort 2, n = 398). Urine specimens from cohort 1 were tested directly by LC–MS/MS, whereas urine specimens from cohort 2 were screened by IA with presumptive positives confirmed by LC–MS/MS. Meconium samples were screened by IA and confirmed by LC–MS/MS at an external laboratory. We evaluated detection of amphetamines, opioids, and cocaine in all specimens. Results In cohort 1, combined testing of maternal and neonatal urine provides equivalent or better sensitivity than combined testing of maternal urine and meconium for pairs that confirmed positive for amphetamines (n = 88, 99% and 97%), opioids (n = 104, 83% and 85%), and cocaine (n = 74, 99% and 64%). Combined testing of neonatal urine and meconium did not improve sensitivity over combinations incorporating maternal urine in this cohort. In cohort 2, IA-based screening was associated with false-positives among both maternal and neonatal specimens, with overall false-positive results of 11% among maternal specimens and 32% among neonatal specimens. Furthermore, combined maternal-neonatal urine testing did not improve sensitivity over combined testing of maternal urine and meconium, and incorporation of neonatal urine did not improve sensitivity over maternal urine or meconium testing alone in this cohort. Conclusions Combined maternal and neonatal urine testing provides equal or better detection of in utero exposure to amphetamines, opioids, and cocaine compared to combinations incorporating meconium when using direct to LC–MS/MS methods but not when IA-based screening is employed. IA-based screening introduced a high false-positive burden, particularly in neonatal specimens, highlighting limitations of screening-first algorithms. Although improved analytical sensitivity does not necessarily equate to greater clinical utility or cost-effectiveness, these findings suggest that integrating maternal urine with neonatal urine testing and selective use of direct LC–MS/MS may improve detection while reducing diagnostic uncertainty when meconium testing is delayed or unavailable.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

30 Evaluation of Paired Maternal and Neonatal Urine Testing Strategies for Detection of In Utero Drug Exposure — Science Skim