  • Results Undocumented resistance marker notifications decreased from 41.3% to 0% within two months, representing a 96% improvement and ensuring reliable communication of critical microbiology results.

Abstract

Introduction/Objective Timely communication of antimicrobial resistance markers is critical to patient safety and antimicrobial stewardship. In our rural Critical Access Hospital (CAH) laboratory, resistance markers such as MRSA, ESBL, and CRE were not automatically flagged in the Laboratory Information System (LIS), requiring manual review by testing personnel. Baseline analysis revealed that 41.3% of microbiology reports with resistance markers lacked documented provider notification, creating risk for delayed treatment, infection control gaps, and regulatory non-compliance. This project aimed to standardize identification, notification, and documentation processes and reduce undocumented notifications to below 5%. Methods/Case Report Lean methodology was applied to evaluate workflow gaps using Value Stream Mapping, SIPOC analysis, GEMBA observation, and Root Cause Analysis. Targeted interventions included standardized SOPs, quick-reference job aides, staff education, LIS notification comments with time-stamped documentation, daily supervisory audits, and KPI monitoring. Results Undocumented resistance marker notifications decreased from 41.3% to 0% within two months, representing a 96% improvement and ensuring reliable communication of critical microbiology results. Conclusion Lean process redesign strengthened result communication, enabling timely clinical decision-making and improving patient safety in a rural CAH laboratory. The initiative achieved 1.7% undocumented notifications within the first quarter, surpassing the < 5 % performance target.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers