Engineering Research Express

Position-dependent group factors for pile dragload due to negative skin friction: evaluation against published model tests

Chenxi Feng, Kun Chen

Computational

Key points

From the paper's conclusion
  • This study proposes a reproducible position-dependent extension of the analytical soil-column model (method L3) and evaluates it alongside the Chinese code JGJ 94-2008 (M1), the finite-element factors of Jeong et al. (1997) (M4) and the uniform soil-column solution (B0) against 88 group-to-single dragload ratios η = Fg/Fs compiled from 58 model-test series across five laboratories under pre-define

Abstract

Estimating the dragload on individual piles in a group subjected to negative skin friction requires group-reduction factors that account for pile position, yet existing design formulations have rarely been benchmarked on a common experimental dataset. This study proposes a reproducible position-dependent extension of the analytical soil-column model (method L3) and evaluates it alongside the Chinese code JGJ 94-2008 (M1), the finite-element factors of Jeong et al. (1997) (M4) and the uniform soil-column solution (B0) against 88 group-to-single dragload ratios η = Fg/Fs compiled from 58 model-test series across five laboratories under pre-defined input rules. Analytical behaviour is governed by the surcharge ratio r = q/(γ′ln), comparing surface surcharge with effective soil weight above the neutral plane, and the hang-up number x = βπdln/As, comparing shaft friction capacity with the net interior column area As. Across the validation sources, JGJ 94-2008 strongly under-predicted η in high-surcharge test configurations (r > 5: source-weighted logarithmic RMSE of 1.72 versus 0.28 for r < 1) because its soil-weight limit omits the surcharge, whereas the fixed factors of Jeong et al. (1997) under-predicted interior piles (RMSE of 0.95), reflecting their derivation for long piles with large x. In the proposed L3 method, enlarging As by 1.5 for edge and 2.25 for corner piles and scaling by an empirical factor (κ = 1.11, calibrated to two centrifuge tests) reduced the validation RMSE from 0.28 (for B0) to 0.13, although it over-predicted one source at close spacing. However, combining group ratios with single-pile dragloads from the full-slip β method—which over-predicted two 1g sources 1.84-fold due to partial friction mobilisation—yielded large absolute dragload errors (RMSE of 0.52). The tests thus support L3 for relative group ratios within x ≤ 3.0 and groups up to 3×3, whereas prototype field tests are required to validate absolute dragload design.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers