Engineering Research Express

Power factor corrected improved-gain SEPIC converter-fed BLDC motor drive for enhanced power quality and torque ripple mitigation

Dileep Kumar, Sneha Kumari, Naresh Kumar Jaishwal, Ramya Soni, Shashi Kala Kumari, Surya Deo Choudhary, Vikash Kumar

Key points

From the paper's conclusion
  • Simulation results over a wide speed range (500–4500 rpm) further verify torque CITR reduction from 24% to 4.7%, confirming the effectiveness of the proposed drive in simultaneously enhancing power quality and suppressing CITR.

Abstract

Brushless dc motor (BLDCM) drives have high commutation-induced torque ripple (CITR) which adversely affects the speed regulation, acoustic noise, vibration levels and the efficiency of the drive. To address this issue, BLDCM drive topologies with dc–dc converters have drawn considerable research interest due to their improved controllability and energy conversion efficiency. The semiconductor devices have nonlinear switching characteristics which causes distortion of the input current waveform resulting in increased harmonics and low power factor (PF). This, in turn, increases the input current, increases conduction losses, thermal stress and challenges in achieving international power quality requirements. In this paper, to overcome these limitations, we propose an improved-gain single-ended primary inductor converter (IG-SEPIC) with PF correction (PFC) stage for BLDCM drive. The proposed architecture successfully mitigates the CITR and enhances the power quality at the input side. The IG-SEPIC is provided with a regulated dc-link supply and has integrated PFC stage that allows for the operation with a near-unity PF and major reduction of the source-side current total harmonics distortion (THD). The proposed drive is validated through numerical simulation and experimental testing. The experimental results at rated operating conditions (48 V, 400 W, and 4500 rpm) demonstrate a reduction in motor-current THD from 59% to 32.1% and source-current THD from 22.8% to 1.90% (with simulated source-current THD of 1.86%). Simulation results over a wide speed range (500–4500 rpm) further verify torque CITR reduction from 24% to 4.7%, confirming the effectiveness of the proposed drive in simultaneously enhancing power quality and suppressing CITR.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Power factor corrected improved-gain SEPIC converter-fed BLDC motor drive for enhanced power quality and torque ripple mitigation — Science Skim