Key points
From the paper's conclusion- Simulation results over a wide speed range (500–4500 rpm) further verify torque CITR reduction from 24% to 4.7%, confirming the effectiveness of the proposed drive in simultaneously enhancing power quality and suppressing CITR.
Abstract
Brushless dc motor (BLDCM) drives have high commutation-induced torque ripple (CITR) which adversely affects the speed regulation, acoustic noise, vibration levels and the efficiency of the drive. To address this issue, BLDCM drive topologies with dc–dc converters have drawn considerable research interest due to their improved controllability and energy conversion efficiency. The semiconductor devices have nonlinear switching characteristics which causes distortion of the input current waveform resulting in increased harmonics and low power factor (PF). This, in turn, increases the input current, increases conduction losses, thermal stress and challenges in achieving international power quality requirements. In this paper, to overcome these limitations, we propose an improved-gain single-ended primary inductor converter (IG-SEPIC) with PF correction (PFC) stage for BLDCM drive. The proposed architecture successfully mitigates the CITR and enhances the power quality at the input side. The IG-SEPIC is provided with a regulated dc-link supply and has integrated PFC stage that allows for the operation with a near-unity PF and major reduction of the source-side current total harmonics distortion (THD). The proposed drive is validated through numerical simulation and experimental testing. The experimental results at rated operating conditions (48 V, 400 W, and 4500 rpm) demonstrate a reduction in motor-current THD from 59% to 32.1% and source-current THD from 22.8% to 1.90% (with simulated source-current THD of 1.86%). Simulation results over a wide speed range (500–4500 rpm) further verify torque CITR reduction from 24% to 4.7%, confirming the effectiveness of the proposed drive in simultaneously enhancing power quality and suppressing CITR.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative Experimental Evaluation of Three Digitally Controlled Boost PFC Topologies for a BLDC Motor DriveInternational Journal of Innovative Science and Research Technology (IJISRT) · 2026
- Design and Experimental Validation of an ISMC-Based Position Controller with Supervisory RBF Neural Network and PIO for BLDC Motor SystemsElectronics · 2026
- Enhanced Ćuk converter topology with dual switches and switched LC cells for high-gain low-power brushless DC motor drivesEngineering Research Express · 2026
- Asymmetric T‐Type PFC Converter With Sensorless Current Control Strategies Based on Different Pulse Width Modulation TechniquesInternational Journal of Circuit Theory and Applications · 2026
- Design and analysis of TOSMC-based BLSEPIC PFC converter for battery charging applicationsScientific Reports · 2026
- Bidirectional Five-Level Asymmetric T-Type Converter with Dual-Interval Current Sensorless Control StrategyElectronics · 2026