Separating temperature from irradiance in outdoor photovoltaic cooling trials: a paired-differential assessment of heat sink and water spray cooling
Felicia Agnes Purnama, Levin Halim
Key points
From the paper's conclusion- Thermocouple temperature differences are indicative: −1.45, −1.08 and −2.12 °C for heat sink, spray and combined treatment.
Abstract
Outdoor photovoltaic cooling trials without an irradiance sensor often quantify the benefit by regressing module power on module temperature, a fit exposed to omitted-variable bias because irradiance drives both. This paper formalises a paired-differential estimator that contrasts each treated module with a simultaneously sampled untreated reference, and states when the common irradiance term cancels: a shared irradiance history, no module-specific shading, soiling or water film, synchronous sampling and an untreated reference. An analytical bound converts residual irradiance mismatch into bias on the open-circuit voltage coefficient. A proposed plausibility screen tests logged short-circuit current and open-circuit voltage of uninstrumented records against a clear-sky plane-of-array envelope. Both tools were applied to a seven-day campaign in Bandung, Indonesia, with four 30 W modules under no cooling, heat sinks, water spray and both (70 hourly records). The modules were canopy-shaded at every sampled hour and not cleaned, and the electrical values were hand-recorded, some entries not independently verifiable. The record fell outside the clear-sky envelope. Short-circuit current reached 3.39 times the clear-sky expectation, and the open-circuit voltage lacked the expected irradiance dependence (−0.002 ± 0.030 V per unit ln G against 0.97 to 1.25 V expected). The electrical results, including a voltage coefficient of −88.2 mV/°C and power gains below 1% reconstructed from V_oc and I_sc at a constant fill factor, are presented as an illustration of the estimator. Thermocouple temperature differences are indicative: −1.45, −1.08 and −2.12 °C for heat sink, spray and combined treatment. With theoretical pump runtime and nameplate power, the sign of the spray energy balance is not determined.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Experimental assessment of active and passive cooling configurations for photovoltaic modules under outdoor conditionsFrontiers in Thermal Engineering · 2026
- Advancing PV temperature modeling: comparative evaluation and a novel empirical modelApplied Thermal Engineering · 2026
- Field Estimation of the Power Temperature Coefficient of a Liquid-Cooled Photovoltaic–Thermal Collector: Sensitivity to Irradiance Normalisation and Model SpecificationEnergies · 2026
- A novel uniform evaporative cooling application for enhancing the performance of photovoltaic modulesProceedings of the Institution of Mechanical Engineers Part E Journal of Process Mechanical Engineering · 2026
- An Irradiance-Normalized Current-Collapse Index for Diagnosing Current-Limited Power Loss in Photovoltaic ModulesEngineering Research Express · 2026
- Photovoltaic Cooling Technologies: Current Developments, Technical Barriers, and Future PerspectivesSymmetry · 2026