BIM integrated sun-path and energy analysis to evaluate self-shading and cooling and heating demand of a G+3 residential building model in four different climate zones in India

Arun Solomon Appadurai, Akila Agnes S

Key points

From the paper's conclusion
  • Purpose: This paper presents a reproducible Building Information Modelling (BIM) workflow that couples sun-path and floor-by-floor shadow analysis with whole-building energy simulation, applying one geometrically invariant residential prototype across the four climatic zones of India to give architects, builders and code authorities indicative, climate-graded shading guidance.
Methods: A G+3 r

Abstract

Purpose: This paper presents a reproducible Building Information Modelling (BIM) workflow that couples sun-path and floor-by-floor shadow analysis with whole-building energy simulation, applying one geometrically invariant residential prototype across the four climatic zones of India to give architects, builders and code authorities indicative, climate-graded shading guidance. Methods: A G+3 reference model of 391.52 m², created in Autodesk Revit 2025, was replicated without geometric change in Chennai (Warm-Humid), Jodhpur (Hot-Dry), New Delhi (Composite) and Shimla (Cold). Shadow plots were generated at nine Indian Standard Time instants per city, and annual energy performance was simulated with the Revit-integrated OpenStudio and EnergyPlus engines using ISHRAE typical-year weather data. In parallel, cast ground-shadow areas were derived analytically for all 36 instants from a rectangular-prism projection, with solar positions from the NREL Solar Position Algorithm. Results: Annual site energy-use intensity (EUI) falls from 479 to 396 kWh m⁻² yr⁻¹ with internal loads held identical, and cooling takes 74.5–81.3 % of site energy in every zone; these are ideal-load results for a fully conditioned scenario, not predictions of metered consumption. The cooling-to-heating ratio falls from infinity at Chennai to about 26 to 1 at Shimla but never inverts. Cast shadow area spans 30–733 m², and the city-mean shadow area correlates inversely with site EUI (r = −0.98, 95 % CI −1.00 to −0.34, p = 0.019, n = 4). An independently built EnergyPlus model verifies the workflow within +6.3 % to +14.2 % of site energy at the three lowland cities and shows that the cloud weather data behind the BIM runs do not resolve Shimla’s 2,202 m highland climate. Conclusions: The indicative shading recommendations and the closed-form shadow-area model give practitioners a reproducible, early-stage design aid for setting façade-specific shading and estimating cast-shadow extent at any Indian site from latitude, orientation and date alone.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers