Engineering Research Express

Design, Manufacturing, and Engineering Validation of an Embedded-FBG Photovoltaic Flexible Cable for Tension Monitoring

Jiazhu Huang, Gongbao Liu, Fengrong Liu, Heli Zhang, Wanxu Zhu

Key points

From the paper's conclusion
  • The results indicate that the proposed sensor integration and protection structure can withstand cable stranding, HDPE sheath extrusion, transportation, on-site installation, and tensioning processes and exhibits good short-term measurement consistency.

Abstract

Flexible photovoltaic (PV) mounting systems rely heavily on pre-tensioned tension cables, whose stress state directly affects structural stiffness, module alignment, and operational safety. This study developed and validated a flexible PV cable with embedded fiber Bragg grating (FBG) sensors for tension monitoring in flexible PV systems. An axial groove was machined on the surface of the center wire of a 1×7 epoxy-coated steel strand, and discrete FBG sensors were bonded into the groove using thermosetting epoxy resin. Subsequently, the center wire equipped with the FBG sensors was re-stranded with six outer steel wires, sheathed with high-density polyethylene (HDPE), and fitted with double-ended fiber optic leads featuring protective structures. In this paper, laboratory-based graded tension calibration tests were conducted on two 10-meter cable specimens, and field installation tests were performed on eight cables with embedded FBG sensors at a 100-MW agro-photovoltaic project in Hainan. Laboratory calibration results showed that the sensitivity at each measurement point ranged from 0.0448 to 0.0454 nm/kN, with a coefficient of determination (R²) consistently above 0.9998; the maximum repeatability error was 0.824%, and the maximum nonlinearity error was 0.952% F.S. During on-site testing, valid data were obtained from all 16 FBG measurement points; no measurement points failed, and the data validity rate was 100%. The maximum difference in calculated cable tension between two adjacent FBG measurement points on the same cable was 1.8 kN, with a maximum absolute relative error of 4.49%. The results indicate that the proposed sensor integration and protection structure can withstand cable stranding, HDPE sheath extrusion, transportation, on-site installation, and tensioning processes and exhibits good short-term measurement consistency. This study provides a feasible FBG sensor integration solution for evaluating the construction quality and monitoring the long-term service performance of tension cables in flexible PV mounting systems.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Design, Manufacturing, and Engineering Validation of an Embedded-FBG Photovoltaic Flexible Cable for Tension Monitoring — Science Skim