Design, Manufacturing, and Engineering Validation of an Embedded-FBG Photovoltaic Flexible Cable for Tension Monitoring
Jiazhu Huang, Gongbao Liu, Fengrong Liu, Heli Zhang, Wanxu Zhu
Key points
From the paper's conclusion- The results indicate that the proposed sensor integration and protection structure can withstand cable stranding, HDPE sheath extrusion, transportation, on-site installation, and tensioning processes and exhibits good short-term measurement consistency.
Abstract
Flexible photovoltaic (PV) mounting systems rely heavily on pre-tensioned tension cables, whose stress state directly affects structural stiffness, module alignment, and operational safety. This study developed and validated a flexible PV cable with embedded fiber Bragg grating (FBG) sensors for tension monitoring in flexible PV systems. An axial groove was machined on the surface of the center wire of a 1×7 epoxy-coated steel strand, and discrete FBG sensors were bonded into the groove using thermosetting epoxy resin. Subsequently, the center wire equipped with the FBG sensors was re-stranded with six outer steel wires, sheathed with high-density polyethylene (HDPE), and fitted with double-ended fiber optic leads featuring protective structures. In this paper, laboratory-based graded tension calibration tests were conducted on two 10-meter cable specimens, and field installation tests were performed on eight cables with embedded FBG sensors at a 100-MW agro-photovoltaic project in Hainan. Laboratory calibration results showed that the sensitivity at each measurement point ranged from 0.0448 to 0.0454 nm/kN, with a coefficient of determination (R²) consistently above 0.9998; the maximum repeatability error was 0.824%, and the maximum nonlinearity error was 0.952% F.S. During on-site testing, valid data were obtained from all 16 FBG measurement points; no measurement points failed, and the data validity rate was 100%. The maximum difference in calculated cable tension between two adjacent FBG measurement points on the same cable was 1.8 kN, with a maximum absolute relative error of 4.49%. The results indicate that the proposed sensor integration and protection structure can withstand cable stranding, HDPE sheath extrusion, transportation, on-site installation, and tensioning processes and exhibits good short-term measurement consistency. This study provides a feasible FBG sensor integration solution for evaluating the construction quality and monitoring the long-term service performance of tension cables in flexible PV mounting systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development and Field Construction Protection of a Fiber Bragg Grating-Geogrid Integrated System in Asphalt PavementsMaterials · 2026
- Graded-Compliance Metal-Packaged FBG Strain Sensor for Cryogenic Strain Measurement of Reusable Launch VehiclesAerospace · 2026
- Programmable direct-patterning assembly enables high-density and surface-conformal integration of fiber Bragg grating sensor arraysNature Communications · 2026
- A Brace-Integrated Fiber Bragg Grating Sensor with a Multi-Hardness Silicone Strain Transfer Substrate for Knee Flexion Monitoring: A Proof-of-Concept Study.Sensors (Basel, Switzerland) · 2026
- Stress Monitoring of a Curved Prestressed Shear Wall in a Fusion Energy Experimental FacilityEngineering Research Express · 2026
- Fiber Bragg Grating-Based Deformation Monitoring in Space Infrastructure: A Comprehensive ReviewJournal of Sensor and Actuator Networks · 2026