Simulation-Based Geometry and Substrate Optimisation of MEMS Piezoresistive Microstructures for Low-Force Human-Interface Sensing

DIVYA R S, Arjunhari M, Suja KJ, Lintu Rajan

Computational

Key points

From the paper's conclusion
  • The results provide a computational design basis for selecting candidate piezoresistive microstructures for subsequent fabrication and experimental validation in low-force human-interface sensing.

Abstract

Low-force human-interface systems require very compact sensors that produce measurable electrical responses under small mechanical loads. This work presents a simulation-based study of diaphragm geometry, piezoresistive microstructure and substrate flexibility in a MEMS piezoresistive force-sensing configuration. Finite-element analyses were performed using COMSOL Multiphysics to compare rectangular, meander-shaped and Archimedean spiral p-type polysilicon piezoresistive microstructures under common diaphragm dimensions, sensing-layer material properties and loading conditions. A square silicon diaphragm of 1 mm x 1 mm was selected following an initial comparison of diaphragm geometries and thicknesses. To further analyse the sensor's adaptability and responsiveness on a flexible substrate, an Archimedean spiral configuration was incorporated onto a polydimethylsiloxane (PDMS) substrate. Under the simulated force range of 0 - 5 N and a bridge excitation of 3 V, the rectangular, meander, and Archimedean spiral configurations exhibited normalised sensitivities of 17.7, 18.7, and 21.7 mV/V/N, respectively, while the PDMS-supported spiral configuration exhibited 23.3 mV/V/N. The spiral therefore produced the highest simulated normalised sensitivity among the geometries examined under the specified modelling conditions. Additional centreline stress-strain and mesh-independence analyses were used to strengthen the numerical comparison. A separate geometrically nonlinear analysis indicated that large-deflection effects become appreciable at approximately 0.45 N using the adopted 5 % displacement-deviation criterion; therefore, the 0-5 N sensitivity values are interpreted as comparative baseline predictions rather than absolute large-deflection performance values. The results provide a computational design basis for selecting candidate piezoresistive microstructures for subsequent fabrication and experimental validation in low-force human-interface sensing.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers