Engineering Research Express

Influence of Installation Position in Roof Cavity on the Aerodynamic Characteristics of Metro Train Double-slider Pantograph

WANG Xianchao, Gang Yang, Yuanxin Ji

Key points

From the paper's conclusion
  • The vicinity of 4.0 m from the left end of the car provides the optimal installation position for the aerodynamic performance. (3) At speed of 70 km/h, when the pantograph is installed in the front-middle section of the roof cavity and the pitch angle of the pantograph head is between -2° and 0°, a strong wake downwash effect will cause a negative aerodynamic lift effect on the rear slider.

Abstract

Based on the actual operating conditions of Type A trains on a specific line of the Hangzhou Metro, to ascertain the influence of installation position on double-slider pantograph's aerodynamic characteristics in a tunnel, Aerodynamic models under different install position were established, ranging from 1.5 m to 4.0 m at intervals of 50 cm. Simultaneously, the aerodynamic drag and lift of the front and rear sliders of the pantograph were obtained. Finally, the variation mechanism of the aerodynamic was explored. The results seem:(1) The aerodynamic forces on both the front and rear sliders are controlled by the flow development of the incoming flow in the cavity shear layer. The aerodynamic lift and drag of dual sliders exhibit significant nonlinear changes with the variation in installation position. As the pantograph position moves backward, the aerodynamic drag and lift of the front slider show an overall downward trend, while the aerodynamic lift and drag of the rear slider show a trend of initially decreasing and then increasing. (2) At each installation position, the difference in aerodynamic lift between the front and rear sliders decreases as the pitch angle increases. The vicinity of 4.0 m from the left end of the car provides the optimal installation position for the aerodynamic performance. (3) At speed of 70 km/h, when the pantograph is installed in the front-middle section of the roof cavity and the pitch angle of the pantograph head is between -2° and 0°, a strong wake downwash effect will cause a negative aerodynamic lift effect on the rear slider.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Influence of Installation Position in Roof Cavity on the Aerodynamic Characteristics of Metro Train Double-slider Pantograph — Science Skim