When Does Calibration-Aware Compilation Transfer to Quantum Hardware? A Three-Processor QAOA Study of Ranking, Drift, and Refresh
Aishwarya Vishwakarma
Key points
From the paper's conclusion- We test whether calibration-aware compiler rankings transfer to hardware using weighted-MaxCut instances implemented with the quantum approximate optimization algorithm (QAOA).
Abstract
Calibration summaries are used both to select physical qubits and to parameterize noisy emulators, creating a risk that agreement within a calibration-derived model is mistaken for validation on hardware. We test whether calibration-aware compiler rankings transfer to hardware using weighted-MaxCut instances implemented with the quantum approximate optimization algorithm (QAOA). The evidence comprises four stages: 3,240 historical calibration-derived simulations; a complete 54-pair hardware grid on three IBM Heron r2 processors; exact-circuit repeats 9.3–12.1 days later; and a contemporaneous five-arm refresh experiment. Full-calibration selection improves the median hardware approximation ratio by 0.74 percentage points (pp), with 29 resolved gains and 11 resolved losses. This is a mean-objective effect: its translation to exact-solution probability is instance- and size-dependent, and we do not extrapolate it beyond the tested n ≤ 10 regime. A Qiskit Aer model constructed from the calibration state available before execution reproduced the direction of the measured full-calibration-versus-topology advantage in 35/54 comparisons, but systematically overestimated its size: the simulated advantage exceeded the subsequently measured hardware advantage by a median 1.35 pp. Regressing the measured hardware advantage on the simulated advantage gave a slope of 0.28 (workload-depth case-cluster 95% interval 0.06–0.52), rather than the unit slope of a calibrated predictor. The emulator identified the exact best of six backend-compiler configurations in only 5/18 cases (95% Wilson interval [0.125, 0.509]). By contrast, identical circuits preserved the compiler-effect sign in 16/18 later repeats (r = 0.92). Refreshing the full-calibration mapping yielded a median +0.72 pp gain, whereas the calibration-score difference agreed in sign with the measured refresh benefit in only 9/18 cases. Calibration data are therefore useful for candidate discovery and timely refresh, but their scalar scores are not calibrated predictors of hardware performance or configuration ranking.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Beyond the Mean Gap: What Transferred-Angle QAOA Retains on a Superconducting ProcessorarXiv · 2026
- Quantum approximate optimization algorithm with cat qubitsScientific Reports · 2026
- Classical simulability and hardware diagnostics for QAOA on geographic coverage benchmarksarXiv · 2026
- Q-Selector: A Data-Driven Framework for Quantum Processor SelectionACM Transactions on Software Engineering and Methodology · 2026
- Integrated error-suppressed pipeline for quantum optimization of nontrivial binary combinatorial optimization problems on gate-model hardware at the 156-qubit scaleNew Journal of Physics · 2026
- A unified framework for calibration, decoding and resource-aware processing in hybrid quantum-classical machine learning.Royal Society open science · 2026