Stable training and confidence‑calibrated generation of urinary stone CT images via physics‑constrained GANs under small‑sample conditions.
Jiangfei Wang, Xinrong Xie, Yaohui Wang, Yuanhao Liu, Yongjie Ma, Wenyong Lian, Liu Na
Shihezi University, shihezi University, Shihezi, Xinjiang, 832003, China. · Shihezi University, Shihezi University, Shihezi, Xinjiang, 832003, China.
Key points
From the paper's conclusion- The proposed framework achieves a competitive FID of 128.0, an Expected Calibration Error (ECE) of 0.072, and a high-risk recall rate of 88% for stone boundary regions, demonstrating its potential for clinically reliable synthetic CT generation.
Abstract
In recent years, artificial intelligence has become integral to modern medicine. Deep learning algorithms are widely used to assist clinical diagnosis, and medical image synthesis has become increasingly mature. However, in small-sample scenarios, synthetic images often overlook infrequent but clinically valuable lesion features. To address the challenges of training instability, insufficient authenticity, and limited clinical usability, we propose a two-stage framework based on Generative Adversarial Networks (GANs). In the first stage, we establish a stable training and physical prior constraint framework for small-sample CT images. Specifically, we incorporate an established asymmetric normalization strategy into the WGAN-GP framework to balance generator convergence and the discriminator's Lipschitz constraint, and we embed a physical noise simulation layer at the discriminator's front end, combined with partial volume effect gradient regularization, to enhance the realism of synthesized images. In the second stage, we employ MC Dropout and deep ensemble methods to quantify uncertainty, generating uncertainty heatmaps and physically consistent confidence maps based on the Poisson-Gaussian noise model. This assists physicians in locating abnormal areas and reducing misdiagnosis risks. Through joint optimization of the generation framework, uncertainty quantification, and confidence image output, the proposed framework effectively resolves issues of mode collapse, low confidence, and poor clinical usability under small-sample conditions. The proposed framework achieves a competitive FID of 128.0, an Expected Calibration Error (ECE) of 0.072, and a high-risk recall rate of 88% for stone boundary regions, demonstrating its potential for clinically reliable synthetic CT generation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Multi-Conditional Diffusion Framework with Texture Constraints for Clinically-Reliable Lesion Synthesis in Virtual Imaging Trials.IEEE transactions on medical imaging · 2026
- A Stable Edge‐Aware GAN Approach for Data Augmentation and Privacy‐Preserving High‐Fidelity CT SynthesisApplied AI Letters · 2026
- Uncertainty as a Proxy for Semantic Correctness in Diffusion-Based Medical Image SynthesisarXiv · 2026
- An efficient approach to synthesize medical images for data augmentation with constrained training dataDiscover Computing · 2026
- Can General-Purpose Generative AI Supply Training Data for Medical Vision Models? A Multimodal Retrospective StudyarXiv · 2026
- The role of generative AI in medical image synthesis: A reviewDiscover Applied Sciences · 2025