B-spline Kolmogorov-Arnold networks for interpretable semi-supervised ECG classification.
Marlin Ramadhan Baidillah, Mitha Rahmawati, Sri Oktamuliani, Rony Febryarto, Pratondo Busono, I Made Astawa, Syaeful Karim, Riyanto Riyanto,
Research Center for Electronics, National Research and Innovation Agency Republic of Indonesia, KST Samaun Samadikun, Bandung, West Java, 40135, Indonesia. · Dept. Physics, Andalas University, Jl. Lingkar Universitas Andalas, Limau Manis, Kec. Pauh,, Padang, West Sumatra, 25163, Indonesia.
Key points
From the paper's conclusion- These results show that
competitive accuracy and inspectable KAN maps can be obtained in one hybrid
architecture.
Abstract
This study investigates how Kolmogorov-Arnold Networks (KANs) behave when combined with semi-supervised learning for single-lead ECG analysis. Three architectures are compared: a standard CNN-BiLSTM-Attention model (accurate but uninterpretable), a minimal KAN with a simple CNN front-end (ablation), and the proposed SE-MSC-KAN-CNN. The proposed model uses multi-scale depthwise convolutions, Squeeze-and-Excitation attention, BiLSTM, and a B-spline KAN head. Interpretability is evaluated in three ways: visualising learned B-spline functions, applying Grad-CAM to highlight important signal regions, and measuring how the splines change when fewer labels are used (spline drift). On the PhysioNet 2017 dataset (8,528 recordings, four classes), the proposed model reaches 85.2% supervised accuracy (F1=0.851), outperforming the CNN baseline (83.1%) and matching much larger black-box models. With only 90% of the labels, it still achieves 85.1%. After training, we applied post-training TFLite INT8 conversion. Only the CNN-front-end KAN converted (measured size 422 KB). The proposed SE-MSC-KAN-CNN did not convert, because Bidirectional LSTM and custom attention lack TFLite kernels; its float32 footprint is about 9.8 MB (theoretical INT8 size about 806 KB). Classification metrics in this paper are float32; INT8 test accuracy was not measured. The spline drift metric summarises how KAN coefficients change under semi-supervised training; use as an on-device out-of-distribution detector is proposed but not validated here. These results show that competitive accuracy and inspectable KAN maps can be obtained in one hybrid architecture. Wearable deployment of the proposed SE-MSC-KAN-CNN is not yet achieved: TFLite INT8 conversion failed, and the present graph still requires float32 inference.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A practitioner’s guide to Kolmogorov–Arnold networksComputer Science Review · 2026
- Taylor-series expanded Kolmogorov–Arnold Network for medical imaging classificationMachine Learning with Applications · 2026
- RecKAN: Kolmogorov-Arnold Networks with a Learnable Recursive Polynomial BasisarXiv · 2026
- Kolmogorov-Arnold Networks: Curse of Dimensionality and Structural BiasarXiv · 2026
- FlashKAN: B-Spline KANs via Truncated Power FormarXiv · 2026
- ER-KANs: Efficient and Robust Kolmogorov-Arnold Networks for Data-Scarce Scientific Machine LearningarXiv · 2026