External evaluation of a deep learning-based algorithm for automated lung tumor and esophagus segmentation on CBCT.
Zhehao Zhang, Dean Hobbis, Jue Jiang, Aneesh Rangnekar, Chloe Min Seo Choi, Michael Waters, Harini Veeraraghavan, Geoffrey D Hugo
Department of Radiation Oncology, Washington University in St Louis, 4921 Parkview Pl, Lower Leve, St. Louis, Missouri, 63130-4899, United States. · Department of Radiation Oncology, Washington University in St Louis, 660 S Euclid Ave, St Louis, Missouri, 63110, United States.
Key points
From the paper's conclusion- For esophagus segmentation, evaluation of 26 scans from 6 patients showed that the model achieved geometric accuracy within peri-target contour rings comparable to rigid propagation, with mean DSC of 0.72 and 0.70, respectively.
Abstract
Online adaptive radiotherapy (ART) requires fast and accurate delineation of targets and organs at risk on cone-beam computed tomography (CBCT). Although deep learning (DL)-based CBCT auto-segmentation methods have been proposed, their clinical generalizability remains insufficiently validated. This study aimed to externally evaluate a pretrained DL model for lung tumor and esophagus segmentation on CBCT. Originally trained using C-arm linac CBCT images, the model was directly applied to an independent cohort of 12 lung cancer patients, each with 5 CBCT images acquired at a separate institution on an O-ring linac. Rigid propagation of planning CT contours served as a minimal baseline to determine whether the model matched or outperformed conventional rigid registration for gross tumor volume (GTV) and esophagus segmentation using geometric and dosimetric measures. Compared with rigid contour propagation, the model significantly improved GTV segmentation accuracy, with mean Dice similarity coefficient (DSC) increasing from 0.66 to 0.76. Significant differences in GTV D98% were observed between the model-generated contours and the reference contours (50.69 vs. 53.58 Gy). The model showed a statistically non-significant decrease in performance compared with previously reported results on its original testing dataset (mean DSC = 0.84), which shared the same distribution as the training dataset. For esophagus segmentation, evaluation of 26 scans from 6 patients showed that the model achieved geometric accuracy within peri-target contour rings comparable to rigid propagation, with mean DSC of 0.72 and 0.70, respectively. Similar esophagus V32Gy values were observed between the model-generated and reference contours (0.06 vs. 0.06 cc). Significantly reduced accuracy was observed compared with previously reported results, with mean DSC decreasing from 0.79 to 0.72. These findings highlight that DL-based CBCT auto-segmentation may suffer performance degradation under domain shifts across patient populations, clinical workflows, and imaging systems, emphasizing the necessity of external evaluation beyond the original development environment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A dual‐prompt framework combining spatial‐mask priors and clinical‐text conditioning for CT‐only GTV delineation in esophageal cancer: A multicenter studyMedical Physics · 2026
- Improving Clinical Target Volume Segmentation Accuracy using Anatomical Priors and Active Learning for the AGITG TOPGEAR Clinical TrialarXiv · 2026
- Integration of AI-Based Synthetic CT Generation and Auto-Segmentation for CBCT-Guided Adaptive Radiotherapy in Prostate Cancer: A Feasibility Study.Cancers · 2026
- Automated offline adaptive radiotherapy through CBCT imaging: A multidimensional feasibility study of hypersight and iterative CBCTJournal of Applied Clinical Medical Physics · 2026
- Cone Beam Computed Tomography-based Lung Function Imaging using Deep Learning for Functional Image-Guided Adaptative Radiation Therapy.International journal of radiation oncology, biology, physics · 2026
- Enhanced diffusion model with 3D structural and segmentation priors for lung cancer radiotherapy dose prediction.Physics in medicine and biology · 2026