Non-thermal argon plasma enhances wettability of Ti-6Al-4V biomaterial surfaces without detectable elemental alteration

ELTHON Luis PUPE, Virgílio Vilas Boas Fernandes Junior, Davidson Ribeiro Costa, Talissa Caroline Pollon, Sheila Cavalca Cortelli, João Maurício Ferraz Da Silva, Rogério De Lima Romeiro

Key points

From the paper's conclusion
  • These findings support non-thermal
argon plasma as a short-term surface-activation strategy for Ti-6Al-4V biomaterials; however,
the durability and biological relevance of this effect require further investigation.

Abstract

This in vitro study evaluated whether non-thermal argon plasma could improve the wettability of Grade 5 titanium alloy (Ti-6Al-4V) surfaces without producing detectable changes in elemental composition. Ninety commercially sourced Ti-6Al-4V discs were allocated to one of three surface conditions: machined, nitric acid-treated, or hydrochloric acid-treated. For wettability analysis, each surface condition was evaluated either without plasma treatment or after 60 s of non-thermal argon plasma exposure at 22 °C, with 13 independent discs per subgroup. Water contact angle was measured using the sessile-drop method, and the mean of the left and right contact angles was used as the specimen-level outcome. Surface morphology and elemental composition were evaluated qualitatively by scanning electron microscopy and energy-dispersive X-ray spectroscopy before plasma exposure and immediately and at 30 and 60 min after treatment. Argon plasma significantly reduced the water contact angle in all surface groups (p < 0.0001), indicating a marked increase in wettability. Mean contact angle decreased from 162.6° to 32.74° on machined surfaces, from 150.5° to 12.96° on nitric acid-treated surfaces, and from 110.0° to 21.87° on hydrochloric acid-treated surfaces. Plasma-treated acid-conditioned surfaces exhibited lower contact angles than plasma-treated machined surfaces. Scanning electron microscopy indicated that plasma exposure made pre-existing topographic features more visually distinct, particularly on acid-treated surfaces, whereas energy-dispersive X-ray spectroscopy revealed no appreciable changes in elemental composition. These findings support non-thermal argon plasma as a short-term surface-activation strategy for Ti-6Al-4V biomaterials; however, the durability and biological relevance of this effect require further investigation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Non-thermal argon plasma enhances wettability of Ti-6Al-4V biomaterial surfaces without detectable elemental alteration — Science Skim