Methods and applications in fluorescence

Algebraic Multicomponent Fluorescence Lifetime Estimation from Harmonic Phase Measurements under Two-Photon Excitation.

Kenji Saijo, Yu Masuda, M Kretkowski, Wataru Inami, Yoshimasa Kawata

Graduate School of Cooperative Major in Medical Photonics, Shizuoka University, 3-5-1 Johoku, Chuo-ku, Hamamatsu city, Shizuoka, Japan, Hamamatsu, , 4328561, Japan. · Faculty of Engineering, Shizuoka University, 3-5-1 Johoku, Chuo-ku, Hamamatsu city, Shizuoka, Japan, Hamamasu, 432-8561, Japan.

Computational

Key points

From the paper's conclusion
  • We formulate and numerically evaluate a direct, non-iterative algebraic estimator for multicomponent fluorescence lifetimes using harmonic phase measurements under two-photon excitation.

Abstract

We formulate and numerically evaluate a direct, non-iterative algebraic estimator for multicomponent fluorescence lifetimes using harmonic phase measurements under two-photon excitation. Complex harmonic responses at the repetition frequency of a femtosecond pulse train and its harmonics are mapped through linear coefficient reconstruction to the denominator polynomial of a rational representation of the multiexponential decay, and the decay constants are obtained from its roots. The method requires neither initial lifetime estimates nor iterative nonlinear minimization. Photon-limited performance was evaluated for a three-component system using Poisson statistics. For closely spaced lifetimes of 0.5, 1.5, and 2.5 ns, the mean relative lifetime error decreased from 14.49% at 100 peak expected photons per time bin to 5.94% at 1000 photons and 1.31% at 10000 photons after averaging 500 statistically independent acquisitions. In a matched 500-trial Monte Carlo comparison at (1 x 107) expected photons per pixel, success probabilities were 0.484, 0.854, and 0.898 for the unconstrained algebraic, DC-constrained algebraic, and single-start nonlinear least-squares (NLLS) estimators, respectively. Thus, the DC constraint substantially improved photon-noise robustness, bringing the algebraic estimator close to NLLS performance. In a separate matched computational benchmark at 1 x 108photons per pixel, median estimation times were 0.138, 0.095, and 5.552 ms per pixel, respectively. These results demonstrate a constraint-induced robustness improvement and a robustness-computation trade-off relative to iterative fitting. The present work is a theoretical and numerical implementation within the established multifrequency frequency-domain framework; experimental validation and harmonic-dependent instrument-response calibration remain necessary for practical two-photon FLIM.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Algebraic Multicomponent Fluorescence Lifetime Estimation from Harmonic Phase Measurements under Two-Photon Excitation — Science Skim