Journal of Optics

Photonic crystal nanocavity refractive-index biosensor for multiple biological samples: A numerical study

Shivesh Kumar, Akash Kumar Pradhan, Kuldeep Yadav, Manoj Kumar

Key points

From the paper's conclusion
  • This numerical study presents a two-dimensional photonic crystal (PhC) nanocavity
biosensor based on a silicon slab for the refractive-index (RI) sensing of multiple biological
samples, namely blood samples associated with tuberculosis, malaria, and dengue, and
hemoglobin concentrations relevant to anemia assessment.

Abstract

This numerical study presents a two-dimensional photonic crystal (PhC) nanocavity biosensor based on a silicon slab for the refractive-index (RI) sensing of multiple biological samples, namely blood samples associated with tuberculosis, malaria, and dengue, and hemoglobin concentrations relevant to anemia assessment. The sensing performance is evaluated using the finite-difference time-domain (FDTD) method by analyzing the resonance wavelength shifts at the output port, while the photonic band structure is investigated using the plane-wave expansion (PWE) method. A 20 nm shift of the cavity-adjacent air hole provides the best overall sensor performance. Two-dimensional FDTD simulations based on the effective-index method yield an idealized sensitivity of 453.85 nm/RIU, a quality factor (QF) of 1.7348 × 105, a figure of merit (FOM) of 4.9740 × 104 RIU−1, and a detection limit (DL) of 2.01045 × 10−6 RIU for dengue-infected plasma. Full three-dimensional FDTD validation of the optimized design, which accounts for all radiative losses, gives a sensitivity of approximately 315 nm/RIU, a QF of 1.39 × 104, a FOM of 2.79 × 103 RIU−1, and a DL of 3.59 × 10−5 RIU for the same analyte. These results confirm the linear RI response of the sensor (R2 ≥ 0.9996), while showing that the 2D model overestimates the absolute QF by approximately one order of magnitude. The sensor also exhibits a linear and predictable thermal response of 98.8 pm/◦C over the range of 0–60 ◦C, which can be used for temperature calibration. A comparison with reported PhC sensors indicates that the proposed design is competitive. A fabrication-tolerance analysis shows that satisfactory sensing performance is maintained under random deviations in hole radius and position of up to 20 nm. With a compact footprint of 76.5 μm2 and compatibility with single-step lithography on a silicon-on-insulator platform, the proposed sensor is a promising candidate for label-free RI sensing in photonic integrated circuits. Surface functionalization and experimental validation will be required for disease-specific detection.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers