Influence of Geometry, Class Imbalance and Alignment on Phantom Reconstruction Accuracy - A Micro-CT Phantom-Based Evaluation.
Avinash Kumar K M, Samarth S Raut
MMAE, Indian Institute of Technology Dharwad, IIT Dharwad, Permanent Campus, Chikkamalligawad, Dharwad, Karnataka, 580011, India. · MMAE, Indian Institute of Technology Dharwad, IIT Dharwad, Permanent Campus, Chikkamalligawad, Dharwad, KA, 580011, India.
Key points
From the paper's conclusion- Although segmentation algorithms are well established, the effects of the type of geometry, class imbalance and voxel and point cloud alignment on accuracy remain to be sufficiently explored.
Abstract
The accuracy of the 3D models created from medical scans depends on every stage of the pipeline - segmentation, alignment, and surface extraction. Although segmentation algorithms are well established, the effects of the type of geometry, class imbalance and voxel and point cloud alignment on accuracy remain to be sufficiently explored. This work evaluates the reconstruction accuracy and also studies the effect of voxel alignment on overlap accuracy metrics using controlled perturbation analysis. A sphere, a facemask, and an abdominal aortic aneurysm (AAA) were printed using the stereolithography technique and scanned using a micro-CT machine. Segmentation was performed using Gaussian Mixture Model (GMM), Otsu thresholding and region-growing (RG) based methods. Segmented and reference models were aligned using the Kabsch-Umeyama (KU) algorithm to evaluate Dice and Jaccard scores, precision, among others. A sensitivity analysis quantified the effect of controlled translational (±5 voxels) and rotational (±5°) perturbations on post-KU-aligned voxel grids. Surface meshes, generated using the marching cubes algorithm, were registered with reference meshes using RANSAC and ICP alignment process. Otsu thresholding yielded highest accuracy for all the geometries. The sphere, with uniform curvature and no thin-walled regions, showed the lowest sensitivity to alignment error. AAA yielded low overlap scores due to its small wall thickness and sensitivity to misalignment. AAA model was most sensitive to misalignment, with Dice and Jaccard scores decreasing by more than 90% under 5° rotation and by over 60% due to just 1°. The facemask surface was most error-prone, possibly due to misalignment during the ICP process. The Jaccard index yields numerically lower values and larger relative changes under perturbations than the Dice score, making alignment sensitivity more apparent for thin-walled structures. Even a sub-millimetre error in voxel alignment adversely affects accuracy. Surface-based accuracy metrics differed from the voxel-based trends, and this divergence carries diagnostic value.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- LatticeRank: Spacing-Ranked Consistency for Native-Grid 3D Medical Image SegmentationarXiv · 2026
- ML-based detection of critical defects in additively manufactured parts via X-ray computed tomographyMaterials & Design · 2025
- Phantom-Free Geometric Refinement for Industrial CBCT Using Physical Constraints and a Normalized Low-Rank Projection Prior.Sensors (Basel, Switzerland) · 2026
- GDLS-D: two-stage medical surface reconstruction via geometric diffusion least squares and iterative deformation optimization.Medical & biological engineering & computing · 2026
- High-fidelity 3D geometric reconstruction of pelvic organs from MRI: a hybrid deep learning and iterative optimization approach.Physics in medicine and biology · 2026
- Fix, Don't Retake: Physics-Simulated Training for Correcting Patient Positioning Errors in Dental Panoramic RadiographsarXiv · 2026