A Quasi-Static Gait Simulator for Testing Transtibial Prostheses: Taking Steps While Standing Still.
Zachary Fine, Clara Phillips, Mark Kortschot, Fae Azhari
University of Toronto, 5 King's College Rd, Toronto, Ontario, M5S 3G8, Canada. · Department of Mechanical and Industrial Engineering, University of Toronto, 5 King's College Road, Toronto, M5S 3G8, Canada.
Key points
From the paper's conclusion- We present a novel gait simulator designed for lab-based testing of transtibial prosthetic sockets.
Abstract
We present a novel gait simulator designed for lab-based testing of transtibial prosthetic sockets. Existing simulators are generally based on complex, expensive treadmill systems. Using the well understood kinetics of gait, we propose a pylon-stationary simulator that uses three electro-pneumatic actuators to replicate the forces and moments experienced by a transtibial prothesis during gait while holding the prosthesis relatively still. We verified the simulator's ability to reproduce specific and general walking gait loads applied to a prosthetic socket using both rigid and compliant mock residual limbs. The simulator accurately replicates vertical and horizontal forces and sagittal plane moments at frequencies up to 0.2 Hz. However, the simulator struggles to replicate sagittal plane moments at higher frequencies, particularly when the socket is highly compliant or poorly fitted. Internal force and moment measurements showed inaccuracies in the presence of large displacements associated with rocking or pistoning, highlighting areas for improvement. Despite its limitations, the proposed simulator provides a versatile and affordable tool for quantitatively assessing prosthetic socket and component performance, or testing novel concepts prior to clinical trials. Future improvements, including enhanced sensor integration, more advanced control schemes, and a user-friendly interface, will expand its utility and impact.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Personalized Prosthetic Socket with Embedded Multi-Location Pressure Sensing TechnologyTechnologies · 2026
- An evaluated gait-driven finite element framework for transfemoral limb–socket interface biomechanics and socket design evaluationJournal of NeuroEngineering and Rehabilitation · 2026
- Design and Bench Evaluation of a Sensor-Integrated Prosthetic-Leg Prototype.Sensors (Basel, Switzerland) · 2026
- Beyond shape capture: The dynamic transtibial prosthetic interface and the continuing role of clinical expertise.Canadian prosthetics & orthotics journal · 2026
- Assistive Trajectory Planning for Lower Limb Exoskeletons: Strategies From Laboratory-Optimized Gait to Environmentally-Adaptive Locomotion Through Multimodal Parameter AwarenessIEEE Reviews in Biomedical Engineering · 2025
- A Scoping Review of Advances in Active Below-Knee Prosthetics: Integrating Biomechanical Design, Energy Efficiency, and Neuromuscular AdaptationProsthesis · 2025